Pregled bibliografske jedinice broj: 920503
Feasibility of setting up generic alert levels for maximum skin dose in fluoroscopically guided procedures
Feasibility of setting up generic alert levels for maximum skin dose in fluoroscopically guided procedures // Physica medica, 46 (2018), 67-74 doi:10.1016/j.ejmp.2018.01.010 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 920503 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Feasibility of setting up generic alert levels for maximum skin dose in fluoroscopically guided procedures
Autori
Järvinen, Hannu ; Farad, Jad ; Siiskonen, Teemu ; Ciraj-Bjelac, Olivera ; Dabin, Jeremie ; Carinou, Eleftheria ; Domienik, Joanna ; Kluszczynski, Dariusz ; Knežević, Željka ; Kopec, Renata ; Majer, Marija ; Malchair, Francoise ; Negri, Anna ; Pankowski, Piotr ; Sarmento, Sandra ; Trianni, Annalisa
Kolaboracija
EURADOS Working Group 12 Dosimetry in medical imaging
Izvornik
Physica medica (1120-1797) 46
(2018);
67-74
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
interventional radiology ; maximum skin dose ; online dose indicator ; skin dose alert
Sažetak
Purpose The feasibility of setting-up generic, hospital-independent dose alert levels to initiate vigilance on possible skin injuries in interventional procedures was studied for three high-dose procedures (chemoembolization (TACE) of the liver, neuro-embolization (NE) and percutaneous coronary intervention (PCI)) in 9 European countries. Methods Gafchromic® films and thermoluminescent dosimeters (TLD) were used to determine the Maximum Skin Dose (MSD). Correlation of the online dose indicators (fluoroscopy time, kerma- or dose-area product (KAP or DAP) and cumulative air kerma at interventional reference point (Ka, r)) with MSD was evaluated and used to establish the alert levels corresponding to a MSD of 2 Gy and 5 Gy. The uncertainties of alert levels in terms of DAP and K a, r, and uncertainty of MSD were calculated. Results About 20-30 % of all MSD values exceeded 2 Gy while only 2-6 % exceeded 5 Gy. The correlations suggest that both DAP and Ka, r can be used as a dose indicator for alert levels (Pearson correlation coefficient p mostly > 0.8), while fluoroscopy time is not suitable (p mostly <0.6). Generic alert levels based on DAP (Gy cm2) were suggested for MSD of both 2 Gy and 5 Gy (for 5 Gy: TACE 750, PCI 250 and NE 400). The suggested levels are close to the lowest values published in several other studies. The uncertainty of the MSD was estimated to be around 10 -15 % and of hospital-specific skin dose alert levels about 20-30 % (with coverage factor k=1). Conclusions The generic alert levels are feasible for some cases but should be used with caution, only as the first approximation, while hospital-specific alert levels are preferred as the final approach.
Izvorni jezik
Engleski
Znanstvena područja
Interdisciplinarne prirodne znanosti, Temeljne medicinske znanosti
POVEZANOST RADA
Ustanove:
Institut "Ruđer Bošković", Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE