Pregled bibliografske jedinice broj: 916078
The Analysis of Channel Characteristics and Implementation of Modem Based on Virtual Instrument in Intra-body Communication
The Analysis of Channel Characteristics and Implementation of Modem Based on Virtual Instrument in Intra-body Communication // Proceedings of the International Conference on Biomedical Engineering and Life Science (BELS 2015)
Lancaster (PA): DEStech Publications, 2015. str. 242-247 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 916078 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The Analysis of Channel Characteristics and Implementation of Modem Based on Virtual Instrument in Intra-body Communication
Autori
Shen, Han-Bin ; Gao, Yue-Ming ; Du, Min ; Vai, Mang- I ; Lučev Vasić, Željka ; Cifrek, Mario
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the International Conference on Biomedical Engineering and Life Science (BELS 2015)
/ - Lancaster (PA) : DEStech Publications, 2015, 242-247
ISBN
978-1-60595-292-5
Skup
International Conference on Biomedical Engineering and Life Science (BELS 2015)
Mjesto i datum
Wuhan, Kina, 14.11.2015. - 15.11.2015
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Intra-body communication ; Galvanic coupling ; Virtual Instrument ; LabVIEW ; Modulation and demodulation
Sažetak
The virtual instrument platform that has the merits of programming intuitively, rapid development and being easy to modify was introduced in this article to study the characteristics or performances of galvanic coupling intra-body communication. Then, the channel capacity of galvanic coupling intra-body communication under 10cm body channel was estimated with Shannon theorem. In addition, the function of modulation and demodulation of real intra-body communication system had been simulated by the way of data acquisition and LabVIEW programming to validate its feasibility in the communication system. What's more, the method of data acquisition and LabVIEW programming could play the role of modulation and demodulation in practical intra-body communication system, and which meant that it was feasible to apply the way to the communication. Moreover, according to the characteristics of body channel, FSK would be much more suitable for intra-body communication system than other two ones.