Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 915550

Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600


Miler, Marijana; Nikolac Gabaj, Nora; Dukić, Lora; Šimundić, Ana-Maria
Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600 // Journal of medical systems, 42 (2017), 28, 12 doi:10.1007/s10916-017-0878-1 (međunarodna recenzija, članak, stručni)


CROSBI ID: 915550 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600

Autori
Miler, Marijana ; Nikolac Gabaj, Nora ; Dukić, Lora ; Šimundić, Ana-Maria

Izvornik
Journal of medical systems (0148-5598) 42 (2017); 28, 12

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni

Ključne riječi
Key performance indicators (KPI) ; Productivity ; Total laboratory automation (TLA) ; Quality

Sažetak
The aim of the study was to estimate improvement of work efficiency in the laboratory after implementation of total laboratory automation (TLA) by Abbott Accelerator a3600 in the laboratory with measuring different key performance indicators (KPIs) before and after TLA implementation. The objective was also to recommend steps for defining KPIs in other laboratories. For evaluation of improvement 10 organizational and/or technical KPIs were defined for all phases of laboratory work and measured before (November 2013) and after (from 2015 to 2017) TLA implementation. Out of 10 defined KPIs, 9 were successfully measured and significantly improved.Waiting time for registration of samples in the LIS was significantly reduced from 16 (9– 28) to 9 (6–16) minutes after TLA (P < 0.001). After TLA all tests were performed at core biochemistry analyzers which significantly reduced walking distance for sample management (for more than 800 m per worker) and number of tube touches (for almost 50%). Analyzers downtime and engagement time for analyzers maintenance was reduced for 50 h and 28 h per month, respectively. TLA eliminated manual dilution of samples with extreme results with sigma values increment from 3.4 to >6 after TLA. Although median turnaround time TAT for potassium and troponin was higher (for approximately 20 min), number of outliers with TAT >60 min expressed as sigma values were satisfying (>3). Implementation of the TLA improved the most of the processes in our laboratory with 9 out of 10 properly defined and measured KPIs. With proper planning and defining of KPIs, every laboratory could measure changes in daily workflow.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti

Napomena
Rad/časopis indeksiran je i u bazama: Mechanical and Transportation Engineering Abstracts ; OCLC WorldCat Discovery Service ; ProQuest ; Reaxys ; Solid State and Superconductivity Abstracts



POVEZANOST RADA


Ustanove:
Klinička bolnica "Sveti Duh",
KBC "Sestre Milosrdnice"

Profili:

Avatar Url Ana-Maria Šimundić (autor)

Avatar Url Nora Nikolac (autor)

Avatar Url Marijana Miler (autor)

Avatar Url Lora Dukić (autor)

Poveznice na cjeloviti tekst rada:

doi link.springer.com doi.org

Citiraj ovu publikaciju:

Miler, Marijana; Nikolac Gabaj, Nora; Dukić, Lora; Šimundić, Ana-Maria
Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600 // Journal of medical systems, 42 (2017), 28, 12 doi:10.1007/s10916-017-0878-1 (međunarodna recenzija, članak, stručni)
Miler, M., Nikolac Gabaj, N., Dukić, L. & Šimundić, A. (2017) Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600. Journal of medical systems, 42, 28, 12 doi:10.1007/s10916-017-0878-1.
@article{article, author = {Miler, Marijana and Nikolac Gabaj, Nora and Duki\'{c}, Lora and \v{S}imundi\'{c}, Ana-Maria}, year = {2017}, pages = {12}, DOI = {10.1007/s10916-017-0878-1}, chapter = {28}, keywords = {Key performance indicators (KPI), Productivity, Total laboratory automation (TLA), Quality}, journal = {Journal of medical systems}, doi = {10.1007/s10916-017-0878-1}, volume = {42}, issn = {0148-5598}, title = {Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600}, keyword = {Key performance indicators (KPI), Productivity, Total laboratory automation (TLA), Quality}, chapternumber = {28} }
@article{article, author = {Miler, Marijana and Nikolac Gabaj, Nora and Duki\'{c}, Lora and \v{S}imundi\'{c}, Ana-Maria}, year = {2017}, pages = {12}, DOI = {10.1007/s10916-017-0878-1}, chapter = {28}, keywords = {Key performance indicators (KPI), Productivity, Total laboratory automation (TLA), Quality}, journal = {Journal of medical systems}, doi = {10.1007/s10916-017-0878-1}, volume = {42}, issn = {0148-5598}, title = {Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600}, keyword = {Key performance indicators (KPI), Productivity, Total laboratory automation (TLA), Quality}, chapternumber = {28} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Uključenost u ostale bibliografske baze podataka::


  • EMBASE (Excerpta Medica)
  • INSPEC
  • METADEX: Metals Science
  • ACM Digital Library
  • Aluminum Industry Abstracts
  • ANTE
  • Corrosion Abstracts
  • Ceramics
  • DBLP, Earthquake Engineering Abstracts
  • EBSCO
  • EMCare
  • Electronics and Communications Abstracts
  • Engineered Materials Abstracts
  • Gale
  • Gale Academic OneFile
  • Google Scholar
  • JCR/Science Edition
  • Materials Business File-Steels Alerts


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font