Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers
Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers // Clinical chemistry and laboratory medicine, 56 (2018), 5; 776-788 doi:10.1515/cclm-2017-0889 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 915543 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers
Autori
Nikolac Gabaj, Nora ; Miler, Marijana ; Vrtarić, Alen ; Hemar, Marina ; Filipi, Petra ; Kocijančić, Marija ; Šupak Smolčić, Vesna ; Ćelap, Ivana ; Šimundić, Ana-Maria
Izvornik
Clinical chemistry and laboratory medicine (1434-6621) 56
(2018), 5;
776-788
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
preanalytical phase ; interference ; hemolysis ; icteria ; lipemia ; serum indices ; analytical verification
Sažetak
Introduction: The aim of our study was to perform verification of serum indices measurement on three clinical chemistry platforms. Materials and methods: This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. Following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Results: Best results for precision were obtained for H index (0.72% to 2.08%). Accuracy for H index was acceptable for Cobas and BC, while on Architect, deviations in high concentration range were observed (y = 0.02 (0.01-0.07) + 1.07 (1.06- 1.08) x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. H index was comparable between BC and both, Architect (Cohen ´s Kappa (95% CI) = 0.795 (0.692-0.898)) and Roche (Cohen´s Kappa (95% CI) = 0.825 (0.729- 0.922)), while Roche and Architect were not comparable. I index was not comparable between all analyzer combinations, while L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when combination of interferences is present. Conclusion: There is heterogeneity between analyzers in HIL quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti, Farmacija
POVEZANOST RADA
Ustanove:
Farmaceutsko-biokemijski fakultet, Zagreb,
Klinička bolnica "Sveti Duh",
KBC "Sestre Milosrdnice"
Profili:
Alen Vrtarić
(autor)
Ana-Maria Šimundić
(autor)
Nora Nikolac
(autor)
Marijana Miler
(autor)
Ivana Ćelap
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE