Pregled bibliografske jedinice broj: 912792
Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer.
Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer. // Graefe's archive for clinical and experimental ophthalmology, 249 (2011), 1; 83-87 doi:10.1007/s00417-010-1546-z (podatak o recenziji nije dostupan, članak, znanstveni)
CROSBI ID: 912792 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer.
Autori
Bjeloš Rončević, Mirjana ; Bušić, Mladen ; Cima, Ivan ; Kuzmanović Elabjer, Biljana ; Bosnar, Damir ; Miletić, Daliborka
Izvornik
Graefe's archive for clinical and experimental ophthalmology (0721-832X) 249
(2011), 1;
83-87
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
Biometry ; Cataract ; Optical low coherence reflectometry ; Partial coherence interferometry
Sažetak
BACKGROUND: The purpose of the study was to assess intraobserver and interobserver repeatability of eight ocular components measurement in cataract eyes using the optical low-coherence reflectometer Lenstar LS 900®. METHODS: Five consecutive measurements of ocular components were taken by two examiners using the Lenstar. Components analyzed were: central corneal thickness, lens thickness, anterior chamber depth, axial length, retinal thickness, keratometry, white-to-white distance, and pupillometry. Within-subject standard deviation and the coefficient of variation were calculated for evaluation of intraobserver repeatability. Bland-Altman analysis was used for assessment of interobserver repeatability. RESULTS: Thirty-two eyes of 22 patients were included. For both observers, the smallest intraobserver coefficient of variation was obtained for axial length, while the largest was found for corneal steepest meridian position. Interobserver repeatability demonstrated less repeatable results for white-to-white distance and corneal steepest meridian position. Considering axial length and anterior chamber depth values, predicted refractive error was 0 ± 0.05 D and 0.02 ± 0.19 D respectively in 95% of observations. CONCLUSION: The Lenstar LS 900® evidenced excellent repeatability and observers´ independent results of all components analyzed except white-to-white distance and corneal steepest meridian position measurements. To the best of our knowledge, this is the first study on interobserver repeatability of optical low-coherence reflectometry in cataract eyes.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Profili:
Mirjana Bjeloš
(autor)
Mladen Bušić
(autor)
Daliborka Miletić
(autor)
Damir Bosnar
(autor)
Biljana Kuzmanović Elabjer
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE