Pregled bibliografske jedinice broj: 908647
Real-time transmittance measurements for assessment of polymerization kinetics of composite materials
Real-time transmittance measurements for assessment of polymerization kinetics of composite materials // Acta stomatologica Croatica
Zagreb, Hrvatska, 2016. str. 170-171 (poster, domaća recenzija, sažetak, znanstveni)
CROSBI ID: 908647 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Real-time transmittance measurements for assessment of polymerization kinetics of composite materials
Autori
Par, Matej ; Marovic, Danijela ; Skenderovic, Hrvoje ; Gamulin, Ozren ; Klaric, Eva ; Tarle, Zrinka
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Acta stomatologica Croatica
/ - , 2016, 170-171
Skup
2nd International congress of the School of Dental Medicine, University of Zagreb
Mjesto i datum
Zagreb, Hrvatska, 2016
Vrsta sudjelovanja
Poster
Vrsta recenzije
Domaća recenzija
Ključne riječi
polymerization kinetics, light transmittance
Sažetak
Objective: To investigate polymerization kinetics of experimental composite materials based on amorphous calcium phosphate (ACP) using real-time transmittance measurements. Materials and methods: Light-curable experimental composite materials were prepared by blending methacrylate resin (67% Bis-EMA, 23% TEGDMA, 10% HEMA) with ACP, barium glass (Ba) and silica (Si) fillers using a dual asymmetric centrifugal mixer. Three ACP-based materials and one control material were prepared (numbers refer to the mass ratio of a certain component): ACP40, ACP40-Ba5Si5, ACP40-Ba9Si1 and Ba40Si10. Tetric EvoCeram was used as a commercial control. Samples in Teflon rings (n=5, diameter= 6 mm, height=2 mm) were sandwiched between glass plates (h=1 mm). During the curing (LED, 30 s, irradiance of 1200 mW/cm2), transmittance was measured at wavelength of 468 nm and time resolution of 20 s-1. Transmittance changes were plotted as a function of time and the initial part of transmittance curve was approximated by a straight line. The obtained slope was assessed as a measure of polymerization rate. Results: The initial part of transmittance curves shows a linear rise lasting for 17-19 seconds for ACP-composites and 7 seconds for Ba40Si10. Mean slope values for materials ACP40, ACP40-Ba5Si5, ACP40-Ba9Si1 and Ba40Si10 were 4.1, 4.6, 4.5 and 7.1 (%/s), respectively. Transmittance curve of the commercial control resembled an exponential shape, with no detectable linear part. Conclusion: A distinct shape of transmittance curves of experimental materials suggests a nearly-constant reaction rate throughout a rather long period of polymerization. This may retard the development of polymerization shrinkage stress, but also impair mechanical properties. The study was supported by CSF programme (08/31).
Izvorni jezik
Engleski
POVEZANOST RADA
Profili:
Danijela Marović
(autor)
Ozren Gamulin
(autor)
Matej Par
(autor)
Zrinka Tarle
(autor)
Hrvoje Skenderović
(autor)