Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 906369

Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production


Janković, Zvonimir; Sierea Atienza, Jaime; Cerdeira Perez, Fernando; Pavković, Branimir
Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production // International journal of refrigeration, 86 (2018), 282-291 doi:10.1016/j.ijrefrig.2017.11.005 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 906369 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production

Autori
Janković, Zvonimir ; Sierea Atienza, Jaime ; Cerdeira Perez, Fernando ; Pavković, Branimir

Izvornik
International journal of refrigeration (0140-7007) 86 (2018); 282-291

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
Heat pump ; Mathematical model ; Desuperheater ; Liquid-vapor heat exchanger ; Experimental results

Sažetak
This paper presents the mathematical modelling of a liquid-to-water heat pump with scroll compressor, brazed plate heat exchangers, additionally built-in liquid-vapor heat exchanger (LVHX) and a desuperheater for domestic hot water (DHW) production. The refrigerant is the zeotropic mixture R407C and the liquid used in the outdoor loop is a propylene-glycol water mixture. Developed mathematical model is validated on experimental data and used as a tool for the heat pump analysis. Simulation results are obtained for the effect of the degree of superheat at the evaporator outlet, the subcooling degree at the condenser outlet, the effect of using or not the LVHX and the effect of using or not the desuperheater for DHW for typical operating conditions of liquid-to-water heat pumps (EN- 14511-2, 2011) in the cooling and heating modes (low and medium temperature applications). Results show that the effect of the degree of superheat or the decision on the suitability of using or not a LVHX may be different for heat pumps that include or not a desuperheater for DHW. In particular, if DHW is a priority, the use of a LVHX is recommended because it leads to higher COP (or EER) values as well as to higher DHW heating powers.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Tehnički fakultet, Rijeka,
Strojarski fakultet, Slavonski Brod

Profili:

Avatar Url Zvonimir Janković (autor)

Avatar Url Branimir Pavković (autor)

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com doi.org

Citiraj ovu publikaciju:

Janković, Zvonimir; Sierea Atienza, Jaime; Cerdeira Perez, Fernando; Pavković, Branimir
Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production // International journal of refrigeration, 86 (2018), 282-291 doi:10.1016/j.ijrefrig.2017.11.005 (međunarodna recenzija, članak, znanstveni)
Janković, Z., Sierea Atienza, J., Cerdeira Perez, F. & Pavković, B. (2018) Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production. International journal of refrigeration, 86, 282-291 doi:10.1016/j.ijrefrig.2017.11.005.
@article{article, author = {Jankovi\'{c}, Zvonimir and Sierea Atienza, Jaime and Cerdeira Perez, Fernando and Pavkovi\'{c}, Branimir}, year = {2018}, pages = {282-291}, DOI = {10.1016/j.ijrefrig.2017.11.005}, keywords = {Heat pump, Mathematical model, Desuperheater, Liquid-vapor heat exchanger, Experimental results}, journal = {International journal of refrigeration}, doi = {10.1016/j.ijrefrig.2017.11.005}, volume = {86}, issn = {0140-7007}, title = {Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production}, keyword = {Heat pump, Mathematical model, Desuperheater, Liquid-vapor heat exchanger, Experimental results} }
@article{article, author = {Jankovi\'{c}, Zvonimir and Sierea Atienza, Jaime and Cerdeira Perez, Fernando and Pavkovi\'{c}, Branimir}, year = {2018}, pages = {282-291}, DOI = {10.1016/j.ijrefrig.2017.11.005}, keywords = {Heat pump, Mathematical model, Desuperheater, Liquid-vapor heat exchanger, Experimental results}, journal = {International journal of refrigeration}, doi = {10.1016/j.ijrefrig.2017.11.005}, volume = {86}, issn = {0140-7007}, title = {Analysis of the impact of different operating conditions on the performance of a reversible heat pump with domestic hot water production}, keyword = {Heat pump, Mathematical model, Desuperheater, Liquid-vapor heat exchanger, Experimental results} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font