Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 899171

Angular dependence of small volume detectors in gamma knife dosimetry


Hršak, Hrvoje; Majer, Marija; Heinrich, Zdravko
Angular dependence of small volume detectors in gamma knife dosimetry // 7th Alpe Adria Medical Physics Meeting : Proceedings / Hršak, Hrvoje ; Budanec, Mirjana (ur.).
Zagreb, 2016. str. 62-69 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 899171 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Angular dependence of small volume detectors in gamma knife dosimetry

Autori
Hršak, Hrvoje ; Majer, Marija ; Heinrich, Zdravko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
7th Alpe Adria Medical Physics Meeting : Proceedings / Hršak, Hrvoje ; Budanec, Mirjana - Zagreb, 2016, 62-69

Skup
7th Alpe Adria Medical Physics Meeting

Mjesto i datum
Zagreb, Hrvatska, 19.05.2016. - 21.05.2016

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Gamma Knife ; Angular dependence ; Diode P ; Diode E

Sažetak
Gamma-Knife radiosurgery is highly precise method for treatment of small intracranial lesions with high single radiation dose [1]. For Leksell Gamma-Knife unit (LGK) Model C (Elekta AB, Stockholm, Sweden) radiosurgery uses 201 convergent narrow Co-60 photon beams, collimated with the 18, 14, 8 and 4 mm helmet collimator. As a part of quality assurance program in Gamma-Knife radiosurgery measurements of output factors should be regularly performed [2]. However, determination of output factors is a nontrivial task, especially for 4 mm collimator. It is associated with a dosimetrical problems such as loss of lateral electronic equilibrium, volumetric averaging of a measured signal and change in a dose response of detector due to a detector density perturbation effects in a presence of small photon field. For dosimetry in the above mentioned conditions detectors should have high spatial resolution, linear dose response, water equivalence and minimal angular dependence. Semiconductor diodes are often used for dosimetry in radiosurgery because of a small measuring volume and therefore high spatial resolution. However, they show considerable angular dependence (up to 10% difference in measured signal between 0° and 90° angle of incident radiation beam) [3]. In this work, angular dependence of small volume detectors used for dosimetry of LGK Model C was investigated and the correction method for angular dependence of detector response was proposed. Correction was based on measurements with Gamma-Knife beams, using two models of p-type silicon diodes (shielded and unshielded) and PinPoint ionization chamber for which angular dependence of response is generally not expected. Shielded Diode P PTW60016 and unshielded Diode E PTW60017 represent good choice for the Gamma- Knife dosimetry because of high spatial resolution and good signal response. However, they are originally designed for dosimetry with their longitudinal axis parallel to the central axis of entering photon or electron beam and they show considerable angular dependence of measured signal, particularly Diode P. Therefore, angular dependence correction should be applied when silicon diodes are used in Gamma-Knife dosimetry. For the 4 mm collimator there is clearly over-response of the diodes due to detector density perturbation effects and an additional field-specific correction should be applied. The PinPoint ionization chamber PTW31006 gives good results for 18 and 14 mm collimators. For the 8 and 4 mm collimator the measured signal is significantly smaller because of the lack of lateral electronic equilibrium, volumetric averaging effect and chamber volume density perturbation effects. The PinPoint chamber should be avoided in Gamma Knife dosimetry for the 8 and 4 mm collimator.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Institut "Ruđer Bošković", Zagreb,
Klinički bolnički centar Zagreb

Profili:

Avatar Url Marija Majer (autor)

Avatar Url Hrvoje Hršak (autor)

Avatar Url Zdravko Heinrich (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada

Citiraj ovu publikaciju:

Hršak, Hrvoje; Majer, Marija; Heinrich, Zdravko
Angular dependence of small volume detectors in gamma knife dosimetry // 7th Alpe Adria Medical Physics Meeting : Proceedings / Hršak, Hrvoje ; Budanec, Mirjana (ur.).
Zagreb, 2016. str. 62-69 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Hršak, H., Majer, M. & Heinrich, Z. (2016) Angular dependence of small volume detectors in gamma knife dosimetry. U: Hršak, H. & Budanec, M. (ur.)7th Alpe Adria Medical Physics Meeting : Proceedings.
@article{article, author = {Hr\v{s}ak, Hrvoje and Majer, Marija and Heinrich, Zdravko}, year = {2016}, pages = {62-69}, keywords = {Gamma Knife, Angular dependence, Diode P, Diode E}, title = {Angular dependence of small volume detectors in gamma knife dosimetry}, keyword = {Gamma Knife, Angular dependence, Diode P, Diode E}, publisherplace = {Zagreb, Hrvatska} }
@article{article, author = {Hr\v{s}ak, Hrvoje and Majer, Marija and Heinrich, Zdravko}, year = {2016}, pages = {62-69}, keywords = {Gamma Knife, Angular dependence, Diode P, Diode E}, title = {Angular dependence of small volume detectors in gamma knife dosimetry}, keyword = {Gamma Knife, Angular dependence, Diode P, Diode E}, publisherplace = {Zagreb, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font