Pregled bibliografske jedinice broj: 894882
Hourly Optimization Model for the Sizing of District Heating Systems Considering Building Refurbishment
Hourly Optimization Model for the Sizing of District Heating Systems Considering Building Refurbishment // 5th International Congress Mechanical Engineers Days
Vodice, Hrvatska, 2017. (predavanje, domaća recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 894882 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Hourly Optimization Model for the Sizing of District Heating Systems Considering Building Refurbishment
Autori
Pavičević, Matija ; Novosel, Tomislav ; Pukšec, tomislav ; Duić, Neven
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
5th International Congress Mechanical Engineers Days
/ - , 2017
Skup
5th International Congress Mechanical Engineers Days
Mjesto i datum
Vodice, Hrvatska, 29.03.2017. - 31.03.2017
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Domaća recenzija
Ključne riječi
District heating ; MILP optimization ; Thermal storage ; Unit commitment problem ; Energy planning
Sažetak
New generations of district heating systems and their ability to utilize renewable resources such as solar and geothermal energy, industrial waste heat, biomass, combined heat and power and power to heat technologies such as heat pumps and electric heaters, is crucial in the development of future energy systems as a whole. In order to fully utilize their benefits, the sizing and operation of these systems needs to be optimized. This is a computationally difficult task due to a large number of parameters that need to be considered and calculated. Another issue is a need for long optimization horizons of at least one year, in order to capture seasonal, and a small time step of one hour or less, to capture intraday variations. The goal of this work has been the development and demonstration of an optimization model capable of handling both the sizing and the operation of a district heating system based on a heat only boiler, solar thermal, electric heaters, heat pumps and heat storage while considering the heating demand reduction due to the building refurbishment. The model has been implemented on five public buildings located in the centre of Buševec. The results from the three analysed scenarios have demonstrated the economic and environmental benefits of the utilization of highly efficient and renewable energy sources in the proposed system.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo
POVEZANOST RADA
Projekti:
120-1201918-1920 - Racionalno skladištenje energije za održivi razvoj energetike (Duić, Neven, MZOS ) ( CroRIS)
Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb
Profili:
Tomislav Novosel
(autor)
Matija Pavičević
(autor)
Tomislav Pukšec
(autor)
Neven Duić
(autor)