Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 891457

Concomitant Valve Sparing Root Remodeling with Extra Aortic Ring Annuloplasty and E-vita Stented Elephant Trunk Implantation


Rudež, Igor; Kušurin, Marko; Planinc, Mislav; Varvodić, Josip; Barić, Davor; Unić, Daniel; Bošnjak, Ante; Blažeković, Robert; Sutlić, Željko
Concomitant Valve Sparing Root Remodeling with Extra Aortic Ring Annuloplasty and E-vita Stented Elephant Trunk Implantation // Heart Valve Society (HVS) Scientific Meeting 2016
New York City (NY), Sjedinjene Američke Države, 2016. (poster, nije recenziran, sažetak, stručni)


CROSBI ID: 891457 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Concomitant Valve Sparing Root Remodeling with Extra Aortic Ring Annuloplasty and E-vita Stented Elephant Trunk Implantation

Autori
Rudež, Igor ; Kušurin, Marko ; Planinc, Mislav ; Varvodić, Josip ; Barić, Davor ; Unić, Daniel ; Bošnjak, Ante ; Blažeković, Robert ; Sutlić, Željko

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni

Izvornik
Heart Valve Society (HVS) Scientific Meeting 2016 / - , 2016

Skup
HVS Scientific Meeting (HVS) Scientific Meeting 2016

Mjesto i datum
New York City (NY), Sjedinjene Američke Države, 17.03.2016. - 19.03.2016

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
Extra Aortic Ring Annuloplasty ; E-vita

Sažetak
Patient Demographics: From November 2014 to October 2015 valve sparing root remodeling technique with external ring annuloplasty was used in twenty patients. From November 2011 to August 2015 E-vita stented elephant trunk procedure was used in eighteen patients, of which fourteen in acute setting. Relevant History: A 49-year-old male, with chronic Stanford B dissection presented to hospital due to paroxysmal atrial fibrillation and chest pain. Transthoracic echocardiography revealed bicuspid aortic valve with AR 2+, dilatation of aortic root up to 40 mm and 42 mm at the level of ST junction. MSCT showed chronic Stanford type B aortic dissection. Dissection spread through the descending aorta down to the level of Th 8, with true lumen diameter 10 x 28 mm, and false lumen diameter 29 x 36 mm at the level of pulmonary bifurcation. Pre-Operative Plan: Valve sparing root remodeling with external subvalvular ring annuloplasty technique is a newly implemented procedure at our department. It represents excellent alternative to patients with AR and concomitant root and ascending aortic dilatation who were previously treated with modified Bentall procedure. E-vita stented elephant trunk is a good modality for treatment of complex cases of aortic pathology which were previously treated with frozen elephant trunk in two stages. Plan was to preserve native aortic valve and stabilize dissected aorta without need for secondary intervention. Discussion of what was actually done and the challenges, deaths and complications encountered. (Unless case is still pending): Peripheral cannulation using axillary artery was performed, aortic root was dissected, cusp free edges were aligned and root remodeling with Gelweave Valsava graft was preformed. Cusps resuspension followed by subvalvular extra-aortic Coroneo ring positioning with coronary ostia reimplantation was done. Circulatory arrest with bilateral antegrade cerebral perfusion was established for 43 minutes during which the stent was deployed and the graft sutured to the distal aorta with separate reimplantation of the supraaoritc branches. Patient recovered uneventfully and early TTE findings show no AR. MSCT showed exclusion of the false lumen. The patient was discharged from hospital nine days after surgery and 3 months following surgery is doing well.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinička bolnica "Dubrava"

Profili:

Avatar Url Igor Rudež (autor)

Avatar Url Robert Blažeković (autor)

Avatar Url Davor Barić (autor)

Avatar Url Daniel Unić (autor)

Avatar Url Željko Sutlić (autor)

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada heartvalvesociety.org

Citiraj ovu publikaciju:

Rudež, Igor; Kušurin, Marko; Planinc, Mislav; Varvodić, Josip; Barić, Davor; Unić, Daniel; Bošnjak, Ante; Blažeković, Robert; Sutlić, Željko
Concomitant Valve Sparing Root Remodeling with Extra Aortic Ring Annuloplasty and E-vita Stented Elephant Trunk Implantation // Heart Valve Society (HVS) Scientific Meeting 2016
New York City (NY), Sjedinjene Američke Države, 2016. (poster, nije recenziran, sažetak, stručni)
Rudež, I., Kušurin, M., Planinc, M., Varvodić, J., Barić, D., Unić, D., Bošnjak, A., Blažeković, R. & Sutlić, Ž. (2016) Concomitant Valve Sparing Root Remodeling with Extra Aortic Ring Annuloplasty and E-vita Stented Elephant Trunk Implantation. U: Heart Valve Society (HVS) Scientific Meeting 2016.
@article{article, author = {Rude\v{z}, Igor and Ku\v{s}urin, Marko and Planinc, Mislav and Varvodi\'{c}, Josip and Bari\'{c}, Davor and Uni\'{c}, Daniel and Bo\v{s}njak, Ante and Bla\v{z}ekovi\'{c}, Robert and Sutli\'{c}, \v{Z}eljko}, year = {2016}, keywords = {Extra Aortic Ring Annuloplasty, E-vita}, title = {Concomitant Valve Sparing Root Remodeling with Extra Aortic Ring Annuloplasty and E-vita Stented Elephant Trunk Implantation}, keyword = {Extra Aortic Ring Annuloplasty, E-vita}, publisherplace = {New York City (NY), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {Rude\v{z}, Igor and Ku\v{s}urin, Marko and Planinc, Mislav and Varvodi\'{c}, Josip and Bari\'{c}, Davor and Uni\'{c}, Daniel and Bo\v{s}njak, Ante and Bla\v{z}ekovi\'{c}, Robert and Sutli\'{c}, \v{Z}eljko}, year = {2016}, keywords = {Extra Aortic Ring Annuloplasty, E-vita}, title = {Concomitant Valve Sparing Root Remodeling with Extra Aortic Ring Annuloplasty and E-vita Stented Elephant Trunk Implantation}, keyword = {Extra Aortic Ring Annuloplasty, E-vita}, publisherplace = {New York City (NY), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font