The accuracy of ultrasonic thickness measurement of distorted grain structure metal samples


Nađ, Nada; Mihaljević, Morana; Keran, Zdenka; Horvatić Novak, Amalija
The accuracy of ultrasonic thickness measurement of distorted grain structure metal samples // Total Quality Management Advanced and Intelligent Approaches Proceedings / Majstorović, V. (ur.).
Beograd: Mechanical Engineering Faculty, Beograd, 2017. str. 133-137 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 881358 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The accuracy of ultrasonic thickness measurement of distorted grain structure metal samples

Autori
Nađ, Nada ; Mihaljević, Morana ; Keran, Zdenka ; Horvatić Novak, Amalija

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Total Quality Management Advanced and Intelligent Approaches Proceedings / Majstorović, V. - Beograd : Mechanical Engineering Faculty, Beograd, 2017, 133-137

ISBN
978-86-7083-934-2

Skup
9th IWC TQM

Mjesto i datum
Beograd, Srbija, 05.06.2017. - 07.06.2017

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Grain elongation, ultrasonic thickness measurement, ultrasonic velocity

Sažetak
Thickness measurement is one of the commonly used control measurements in sheet metal forming. Ultrasonic thickness measurement systems demand access to the material only from one side which makes them very useful for this purpose. Distortion of grain structure of the workpiece influences ultrasonic velocity and in that way directly influences ultrasonic thickness measurement. Three different ultrasonic thickness measurement systems are examined on the same working sample. Two systems are defined by standard EN14127. The third system is not defined by the standard and includes previously measured ultrasonic velocity in specific direction of grain elongation. Statistical analysis shows relations between measurement results obtained by all three systems and highlights the third system as the most accurate one.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo



POVEZANOST RADA


Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb


Citiraj ovu publikaciju:

Nađ, Nada; Mihaljević, Morana; Keran, Zdenka; Horvatić Novak, Amalija
The accuracy of ultrasonic thickness measurement of distorted grain structure metal samples // Total Quality Management Advanced and Intelligent Approaches Proceedings / Majstorović, V. (ur.).
Beograd: Mechanical Engineering Faculty, Beograd, 2017. str. 133-137 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Nađ, N., Mihaljević, M., Keran, Z. & Horvatić Novak, A. (2017) The accuracy of ultrasonic thickness measurement of distorted grain structure metal samples. U: Majstorović, V. (ur.)Total Quality Management Advanced and Intelligent Approaches Proceedings.
@article{article, author = {Na\dj, Nada and Mihaljevi\'{c}, Morana and Keran, Zdenka and Horvati\'{c} Novak, Amalija}, editor = {Majstorovi\'{c}, V.}, year = {2017}, pages = {133-137}, keywords = {Grain elongation, ultrasonic thickness measurement, ultrasonic velocity}, isbn = {978-86-7083-934-2}, title = {The accuracy of ultrasonic thickness measurement of distorted grain structure metal samples}, keyword = {Grain elongation, ultrasonic thickness measurement, ultrasonic velocity}, publisher = {Mechanical Engineering Faculty, Beograd}, publisherplace = {Beograd, Srbija} }
@article{article, author = {Na\dj, Nada and Mihaljevi\'{c}, Morana and Keran, Zdenka and Horvati\'{c} Novak, Amalija}, editor = {Majstorovi\'{c}, V.}, year = {2017}, pages = {133-137}, keywords = {Grain elongation, ultrasonic thickness measurement, ultrasonic velocity}, isbn = {978-86-7083-934-2}, title = {The accuracy of ultrasonic thickness measurement of distorted grain structure metal samples}, keyword = {Grain elongation, ultrasonic thickness measurement, ultrasonic velocity}, publisher = {Mechanical Engineering Faculty, Beograd}, publisherplace = {Beograd, Srbija} }




Contrast
Increase Font
Decrease Font
Dyslexic Font