Radiological findings in Egyptian canopic jars – comparing the three standard clinical imaging modalities (conventional X-ray, CT and MRI)


Eppenberger, Patrick; Čavka, Mislav; Šćukanec, Porin; Ruehli, Frank
Radiological findings in Egyptian canopic jars – comparing the three standard clinical imaging modalities (conventional X-ray, CT and MRI) // Paleopathology Association 44th Annual North American Meeting, Abstract Book
New Orleans (LA), Sjedinjene Američke Države, 2017. str. 23-23 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 873809 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Radiological findings in Egyptian canopic jars – comparing the three standard clinical imaging modalities (conventional X-ray, CT and MRI)

Autori
Eppenberger, Patrick ; Čavka, Mislav ; Šćukanec, Porin ; Ruehli, Frank

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Paleopathology Association 44th Annual North American Meeting, Abstract Book / - , 2017, 23-23

Skup
Paleopathology Association 44th Annual North American Meeting

Mjesto i datum
New Orleans (LA), Sjedinjene Američke Države, 17.04.2017. - 19.04.2017

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
paleoradiology, Ancient Egypt, CT, MRI, X-ray, Croatia, canopics

Sažetak
Originating from an imitation of natural dehydration processes of prehistoric burials in the desert, the continuously refined mummification procedures in ancient Egypt involved the use of canopic jars, to store and preserve internal organs, previously removed from the body. The aim of this study was to assess organ remains contained in canopic jars with the three standard clinical imaging modalities conventional X-ray, computed tomography (CT) and magnetic resonance imaging (MRI) with regard to the specific tissue alterations caused by embalming and postmortem dehydration processes. For this purpose three Horus-children-headed canopic jars from the Egyptian collection of the archaeological museum in Zagreb were imaged. As expected, conventional X-ray and CT provided superior detail over MRI, mainly because of the higher spatial resolution. However, the high density of the travertine, of which the three examined canopic jars were made, limited the image quality of conventional X-ray images. CT scans, in contrast, showed very little artifacts and revealed structures of organ-specific morphology (intestine) of higher density (c. 400 HU), which are very clearly distinguishable from the surrounding embalming material of homogenous density (c. 250 HU). Furthermore, despite of the significantly lower spatial resolution, MRI images provided important additional information. Unexpected pronounced variations in signal intensity coincided well with the structures identified in the CT scans. These radiological findings, are thus highly compatible with the putatively contained organs in accordance to the inscriptions and dedicated deity of the examined canopic jars. A further histological and genetic analysis is expected to confirm our presented results.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti, Arheologija



POVEZANOST RADA


Ustanove:
Medicinski fakultet, Zagreb,
Klinička bolnica "Dubrava",
Arheološki muzej u Zagrebu

Profili:

Avatar Url MISLAV ČAVKA (autor)


Citiraj ovu publikaciju:

Eppenberger, Patrick; Čavka, Mislav; Šćukanec, Porin; Ruehli, Frank
Radiological findings in Egyptian canopic jars – comparing the three standard clinical imaging modalities (conventional X-ray, CT and MRI) // Paleopathology Association 44th Annual North American Meeting, Abstract Book
New Orleans (LA), Sjedinjene Američke Države, 2017. str. 23-23 (poster, međunarodna recenzija, sažetak, znanstveni)
Eppenberger, P., Čavka, M., Šćukanec, P. & Ruehli, F. (2017) Radiological findings in Egyptian canopic jars – comparing the three standard clinical imaging modalities (conventional X-ray, CT and MRI). U: Paleopathology Association 44th Annual North American Meeting, Abstract Book.
@article{article, author = {Eppenberger, Patrick and \v{C}avka, Mislav and \v{S}\'{c}ukanec, Porin and Ruehli, Frank}, year = {2017}, pages = {23-23}, keywords = {paleoradiology, Ancient Egypt, CT, MRI, X-ray, Croatia, canopics}, title = {Radiological findings in Egyptian canopic jars – comparing the three standard clinical imaging modalities (conventional X-ray, CT and MRI)}, keyword = {paleoradiology, Ancient Egypt, CT, MRI, X-ray, Croatia, canopics}, publisherplace = {New Orleans (LA), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }
@article{article, author = {Eppenberger, Patrick and \v{C}avka, Mislav and \v{S}\'{c}ukanec, Porin and Ruehli, Frank}, year = {2017}, pages = {23-23}, keywords = {paleoradiology, Ancient Egypt, CT, MRI, X-ray, Croatia, canopics}, title = {Radiological findings in Egyptian canopic jars – comparing the three standard clinical imaging modalities (conventional X-ray, CT and MRI)}, keyword = {paleoradiology, Ancient Egypt, CT, MRI, X-ray, Croatia, canopics}, publisherplace = {New Orleans (LA), Sjedinjene Ameri\v{c}ke Dr\v{z}ave} }




Contrast
Increase Font
Decrease Font
Dyslexic Font