Pregled bibliografske jedinice broj: 873121
The electrode setup for vibratory evoked potentials
The electrode setup for vibratory evoked potentials // Proceedings of the International Conference on Medical and Biological Engineering 2017 / Badnjević, Almir (ur.).
Sarajevo, Bosna i Hercegovina: Springer, 2017. str. 557-562 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 873121 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The electrode setup for vibratory evoked potentials
Autori
Krbot Skorić, Magdalena ; Cifrek, Mario ; Krois, Igor ; Jerbić, Ana Branka ; Išgum, Velimir
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the International Conference on Medical and Biological Engineering 2017
/ Badnjević, Almir - : Springer, 2017, 557-562
ISBN
978-981-10-4166-2
Skup
International Conference on Medical and Biological Engineering in Bosnia and Herzegovina (CMBEBIH 2017)
Mjesto i datum
Sarajevo, Bosna i Hercegovina, 16.03.2017. - 18.03.2017
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
the sense of vibration, vibratory evoked potentials, vibratory stimulation, number of electrodes
Sažetak
The difficulties related to the sense of vibration could be characteristics of the specific neurological disorders, so there is a need for measurable and quantifiable information about its functionality. Currently used methods for testin g the sense of vibration do not provide appropriate information, and new method of vibratory stimulation was introduced in the area of the neurophysiological research. Method provides repeatable and quantifiable information about the evoked cortical activi ty, but there was a need for information about the functional integrity of the whole vibratory sensory pathways. The result of this research was the electrode setup that provides information from the Erb’s point through the levels of the cervical spine to the contralateral sensory area at the cortex. Also, the setup consists only of four electrodes for each side of the stimulation (six electrodes all together, because electrodes positioned on the cervical spinal cord are common for both sides of the body), which reduce time necessary for preparation and allows better use for clinical purposes
Izvorni jezik
Engleski
POVEZANOST RADA
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb,
Klinički bolnički centar Zagreb
Profili:
Velimir Išgum (autor)
Igor Krois (autor)
Ana Branka Jerbić (autor)
MAGDALENA KRBOT SKORIĆ (autor)
Mario Cifrek (autor)