Development of Computer System for Digital Measurement of Human Body: Initial Findings


Katović, Darko; Gruić, Igor; Bušić, Anita; Bronzin, Tomislav; Pažin, Krešimir; Bolčević, Filip; Medved, Vladimir; Mišigoj-Duraković, Marjeta
Development of Computer System for Digital Measurement of Human Body: Initial Findings // Proceedings of the 4th International Congress on Sport Sciences Research and Technology Support / Pedro Pezarat Correia and Jan Cabri (ur.).
Porto: SCITEPRESS, 2016. str. 147-153 doi:10.5220/0006086001470153 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 861303 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Development of Computer System for Digital Measurement of Human Body: Initial Findings

Autori
Katović, Darko ; Gruić, Igor ; Bušić, Anita ; Bronzin, Tomislav ; Pažin, Krešimir ; Bolčević, Filip ; Medved, Vladimir ; Mišigoj-Duraković, Marjeta

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 4th International Congress on Sport Sciences Research and Technology Support / Pedro Pezarat Correia and Jan Cabri - Porto : SCITEPRESS, 2016, 147-153

ISBN
978-989-758-205-9

Skup
IcSPORTS 2016 - 4th International Congress on Sport Sciences Research and Technology Support

Mjesto i datum
Porto, Portugal, 07.11.2016. - 09.11.2016

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Anthropometry ; Measurement Reliability ; Kinect ; Protocol Modelling

Sažetak
Background: Microsoft Kinect is used in the field of anthropometry (Sameijma et al., 2012 ; Xu et al., 2013 ; Clarkson et al., 2016 ; Zhang et al., 2015), gait analysis (Springer & Seligman, 2016 ; Pfister et al., 2014 ; Motiian et al., 2015 ; Prochazka et al., 2015 ; Cippitelli et al., 2015), motor performance (Lim et al., 2015 ; Sevick et al., 2016 ; Taha et. al., 2016), posture/balance evaluation (Dutta et al., 2014 ; Metiplay et al., 2013 ; Oh et al., 2014 ; Saenz-de-Urturi & Garcia- Zapirain Soto, 2016) and rehabilitation (Galna et al., 2014 ; Mobini et al., 2015 ; De Rosario et al., 2014 ; Shapi’i et al., 2015). Reliability of instruments in clinical and sport application differ, therefore the goal of this research was to initially determine the protocol of validation of a new measuring instrument for digital measurement of anthropometric dimensions of the body structural and metric). Reliability of results in this paper was tested on three classically and digitally measured anthropometric variables, i.e. height, left forearm length and left lower leg length. Methods: Male and female employees of the Technology Park Zagreb (N=52) volunteered for this research. Subjects were wearing their everyday clothes. Among 471 assessed variables (3 + ((26 * 6)) * 3) three variables from a set of classically measured anthropometric dimensions were extracted - height, length of left forearm and length of left lower leg. Classical measurements were conducted through standard IBP protocols, a Standardized protocol for digital measurement (DM- I) was produced. Data were analyzed by Statistica 12 for Windows operating system. Mean, standard deviation, range, variability coefficient, skewness and kurtosis were used as descriptive parameters, as well as Pearson correlation coefficient, Spearman-Brown alpha, Cronbach`s alpha and Spearman-Brown (standardized) alpha. Results: Classically and digitally measured height in average results do not differ significantly, while for lengths of the left forearm and the left lower leg do indicate significant differences (lower values). The differences could be attributed to different reference points used in two measurement methods. Measures of internal consistency (reliability) for digitally measured variables:height of the body, length of left forearm and length of left lower leg demonstrate high reliability (Cronbach alpha, the standardized alpha 0.995 to 0.997) and the average inter-item correlation (0.973 to 0.985), indicates a high internal consistency between items related to digitally measured height. Reliability was slightly lower for digitally measured length of the left forearm and lower leg due to greater differentiation in average interitem correlations coefficients. Conclusions: Digital measurements with Kinect are not appropriate for clinical trials demanding high precision. There is no statistical evidence that could differentiate distances of examinee from Kinect sensor in order to define optimal distance (as long as subject stands within Kinects range. Small errors occur due to clothing, possibly due to illumination, and sensor height and distance, which is in line with previous research.

Izvorni jezik
Engleski

Znanstvena područja
Grafička tehnologija, Računarstvo, Biotehnologija, Informacijske i komunikacijske znanosti



POVEZANOST RADA


Ustanove:
Kineziološki fakultet, Zagreb,
Visoko učilište Algebra, Zagreb

Poveznice na cjeloviti tekst rada:

Pristup cjelovitom tekstu rada doi

Citiraj ovu publikaciju:

Katović, Darko; Gruić, Igor; Bušić, Anita; Bronzin, Tomislav; Pažin, Krešimir; Bolčević, Filip; Medved, Vladimir; Mišigoj-Duraković, Marjeta
Development of Computer System for Digital Measurement of Human Body: Initial Findings // Proceedings of the 4th International Congress on Sport Sciences Research and Technology Support / Pedro Pezarat Correia and Jan Cabri (ur.).
Porto: SCITEPRESS, 2016. str. 147-153 doi:10.5220/0006086001470153 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Katović, D., Gruić, I., Bušić, A., Bronzin, T., Pažin, K., Bolčević, F., Medved, V. & Mišigoj-Duraković, M. (2016) Development of Computer System for Digital Measurement of Human Body: Initial Findings. U: Pedro Pezarat Correia and Jan Cabri (ur.)Proceedings of the 4th International Congress on Sport Sciences Research and Technology Support doi:10.5220/0006086001470153.
@article{article, author = {Katovi\'{c}, Darko and Grui\'{c}, Igor and Bu\v{s}i\'{c}, Anita and Bronzin, Tomislav and Pa\v{z}in, Kre\v{s}imir and Bol\v{c}evi\'{c}, Filip and Medved, Vladimir and Mi\v{s}igoj-Durakovi\'{c}, Marjeta}, year = {2016}, pages = {147-153}, DOI = {10.5220/0006086001470153}, keywords = {Anthropometry, Measurement Reliability, Kinect, Protocol Modelling}, doi = {10.5220/0006086001470153}, isbn = {978-989-758-205-9}, title = {Development of Computer System for Digital Measurement of Human Body: Initial Findings}, keyword = {Anthropometry, Measurement Reliability, Kinect, Protocol Modelling}, publisher = {SCITEPRESS}, publisherplace = {Porto, Portugal} }
@article{article, author = {Katovi\'{c}, Darko and Grui\'{c}, Igor and Bu\v{s}i\'{c}, Anita and Bronzin, Tomislav and Pa\v{z}in, Kre\v{s}imir and Bol\v{c}evi\'{c}, Filip and Medved, Vladimir and Mi\v{s}igoj-Durakovi\'{c}, Marjeta}, year = {2016}, pages = {147-153}, DOI = {10.5220/0006086001470153}, keywords = {Anthropometry, Measurement Reliability, Kinect, Protocol Modelling}, doi = {10.5220/0006086001470153}, isbn = {978-989-758-205-9}, title = {Development of Computer System for Digital Measurement of Human Body: Initial Findings}, keyword = {Anthropometry, Measurement Reliability, Kinect, Protocol Modelling}, publisher = {SCITEPRESS}, publisherplace = {Porto, Portugal} }

Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font