Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration


Bajs, Tomislav; Krajnc, Božidar
Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration // Nuclear Option in Countries with Small and Medium Electricity Grid / Knapp, Vladimir ; Čavlina, Nikola (ur.).
Opatija, Hrvatska: Hrvatsko nuklearno društvo, 1996. str. 478-487 (poster, nije recenziran, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 8426 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration

Autori
Bajs, Tomislav ; Krajnc, Božidar

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Nuclear Option in Countries with Small and Medium Electricity Grid / Knapp, Vladimir ; Čavlina, Nikola - : Hrvatsko nuklearno društvo, 1996, 478-487

Skup
International Conference: Nuclear Option in Countries with Small and Medium Electricity Grid

Mjesto i datum
Opatija, Hrvatska, 07.10.1996. - 09.10.1996

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Ključne riječi
NPP safety; medium break loss of coolant accident; accumulators

Sažetak
Medium break loss of coolant accident is in probabilistic safety analysis typically defined as break size for which high pressure injection system with single failure criteria is sufficient to mitigate consequences of the accident, e.g. to maintain rod temperatures bellow damage criteria. Consequently, break sizes for whose mitigation low pressure injection system is essential, are assumed to fall in large break loss of coolant category. In this report, best-estimate thermohydraulic code RELAP5/mod2 has been used to determine the role of accumulators on the system response for different break sizes. Outcome of the analysis has shown that most severe break sizes, with respect to the rod temperature are: 5 in equivalent break size for medium break and 12 in equivalent break size for large break. The results of RELAP5/mod2 analysis have been compared with MAAP results from NEK (Nuklearna Elektrana Krško) IPE (Individual Plant Examination) level1/level2 integration and major differences in the results were discussed.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036010

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Tomislav Bajs (autor)


Citiraj ovu publikaciju:

Bajs, Tomislav; Krajnc, Božidar
Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration // Nuclear Option in Countries with Small and Medium Electricity Grid / Knapp, Vladimir ; Čavlina, Nikola (ur.).
Opatija, Hrvatska: Hrvatsko nuklearno društvo, 1996. str. 478-487 (poster, nije recenziran, cjeloviti rad (in extenso), znanstveni)
Bajs, T. & Krajnc, B. (1996) Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration. U: Knapp, V. & Čavlina, N. (ur.)Nuclear Option in Countries with Small and Medium Electricity Grid.
@article{article, author = {Bajs, Tomislav and Krajnc, Bo\v{z}idar}, year = {1996}, pages = {478-487}, keywords = {NPP safety, medium break loss of coolant accident, accumulators}, title = {Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration}, keyword = {NPP safety, medium break loss of coolant accident, accumulators}, publisher = {Hrvatsko nuklearno dru\v{s}tvo}, publisherplace = {Opatija, Hrvatska} }
@article{article, author = {Bajs, Tomislav and Krajnc, Bo\v{z}idar}, year = {1996}, pages = {478-487}, keywords = {NPP safety, medium break loss of coolant accident, accumulators}, title = {Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration}, keyword = {NPP safety, medium break loss of coolant accident, accumulators}, publisher = {Hrvatsko nuklearno dru\v{s}tvo}, publisherplace = {Opatija, Hrvatska} }