Pregled bibliografske jedinice broj: 841794
SORIN FREEDOM SOLO STENTLESS VALVE IN SURGICAL THERAPY OF AORTIC VALVE ENDOCARDITIS: INITIAL RESULTS AND MID-TERM FOLLOW UP
SORIN FREEDOM SOLO STENTLESS VALVE IN SURGICAL THERAPY OF AORTIC VALVE ENDOCARDITIS: INITIAL RESULTS AND MID-TERM FOLLOW UP // International Journal of Antimicrobial Agents / Geddes, A.M. (ur.).
Dubrovnik, Hrvatska: Elsevier, 2013. str. S32-S32 (predavanje, recenziran, sažetak, stručni)
CROSBI ID: 841794 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
SORIN FREEDOM SOLO STENTLESS VALVE IN SURGICAL THERAPY OF AORTIC VALVE ENDOCARDITIS: INITIAL RESULTS AND MID-TERM FOLLOW UP
Autori
Rudež, Igor ; Varvodić, Josip ; Matić, Ivica ; Barić, Davor ; Unić, Daniel ; Blažeković, Robert ; Planinc, Mislav ; Sutlić, Željko ; Baršić, Bruno
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, stručni
Izvornik
International Journal of Antimicrobial Agents
/ Geddes, A.M. - : Elsevier, 2013, S32-S32
Skup
International Symposium on Modern Concepts in Endocarditis and Cardiovascular Infections
Mjesto i datum
Dubrovnik, Hrvatska, 19.05.2013. - 21.05.2013
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Recenziran
Ključne riječi
surgical therapy ; endocarditis
Sažetak
Background: Despite significant improvement in antibiotic therapy, aortic valve endocarditis, with or without perivalvular abscess, still represents significant surgical challenge. Homograft implantation is the gold standard of surgical therapy, but new artificial valves attract more attention due to easier availability. We present our results in utilizing the Sorin Freedom SOLO stentless aortic valve in surgical management of aortic valve endocarditis. Methods: From January 2009 until January 2013, seventeen male patients underwent aortic valve replacement due to aortic valve endocarditis utilizing the Sorin Freedom SOLO bioprosthesis made of bovine pericardium. Follow-up and postoperative echo data were collected in a prospective manner. Results: There were 9 emergent surgeries (56%), 5 urgent (31%), and 2 elective (13%). Average age was 61.5±8.74 years (range 43–76) with median EuroSCORE 10, and logistic EuroSCORE mortality 23.09±20.09% (4.4–59.7%). One patient underwent concomitant mitral valve replacement, and four patients had annular abscesses which were closed with glutaraldehyde treated autologous pericardium. Average aortic cross-clamp time for isolated aortic valve replacement was 58.81±19.25 minutes (42–98), and for combined procedures (mitral valve replacement, closure of subannular abscess) 112.8±22.6 minutes (82–141). Median valve size was 25mm (23–27). Follow up was 18.98±14.49 months (0.1–43.86). Two patients died during hospital stay due to multi-organ failure, and one died during mid-term follow-up, for an overall mortality of 18%. Early mean postoperative transvalvular gradient was 11.22±4.36 mmHg(7– 15.8), and medium-term gradient was 12.5±5.6 mmHg. During follow-up, there were neither structural valve deterioration of any kind nor prosthetic valve endocarditis. Conclusion: Because of its specific implantation technique with single supra- annular suture line, and absence of any artificial material in its design, Sorin Freedom SOLO stentless bioprosthesis is a valuable tool in surgical management of aortic valve endocarditis. Although our initial results are encouraging, further follow-up is necessary.
Izvorni jezik
Engleski
Znanstvena područja
Kliničke medicinske znanosti
POVEZANOST RADA
Ustanove:
Klinička bolnica "Dubrava",
Medicinski fakultet, Osijek
Profili:
Ivica Matić
(autor)
Daniel Unić
(autor)
Davor Barić
(autor)
Željko Sutlić
(autor)
Bruno Baršić
(autor)
Igor Rudež
(autor)
Robert Blažeković
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus
- MEDLINE