Pregled bibliografske jedinice broj: 824328
CORRELATION BETWEEN ION RELEASE, WIRE TYPE AND ACIDITY VALUES OF ARTIFICIAL SALIVA OF NICKEL- TITANIUM WIRES WITH DIFFERENT COATINGS
CORRELATION BETWEEN ION RELEASE, WIRE TYPE AND ACIDITY VALUES OF ARTIFICIAL SALIVA OF NICKEL- TITANIUM WIRES WITH DIFFERENT COATINGS // European Journal of Orthodontics / David Rice (ur.).
Stockholm, Švedska: Oxford University Press, 2016. str. e121-e121 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 824328 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
CORRELATION BETWEEN ION RELEASE, WIRE TYPE AND ACIDITY VALUES OF ARTIFICIAL SALIVA OF NICKEL- TITANIUM WIRES WITH DIFFERENT COATINGS
Autori
Katić, Višnja ; Blagović, Branka ; Ciganj, Zlatko ; Pavlić, Andrej ; Špalj, Stjepan
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
European Journal of Orthodontics
/ David Rice - : Oxford University Press, 2016, E121-e121
Skup
92nd Congress of the European Orthodontic Society
Mjesto i datum
Stockholm, Švedska, 11.06.2016. - 16.06.2016
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
artificial saliva; orthodontic archwires; ion release
Sažetak
AIM: To explore correlation between ion release, wire type and acidity values of artificial saliva of nickel-titanium wires with different coatings. MATERIALS AND METHOD: Uncoated (NiTi) and rhodium-coated (RhNiTi) nickel-titanium wires were immersed in artificial saliva solutions (1.5 g/l KCl, 1.5 g/l NaHCO3, 0.5 g/l, NaH2PO4–H2O, 0.5 g/l KSCN, 0.9 g/l lactic acid). The pH values were adjusted to 5.5 and 6.6 with the use of lactic acid and NaOH. Specimens were incubated at 37 °C for 28 days. Released nickel and titanium ions were measured by means of inductively coupled plasma-optical emission spectroscopy (ICP-OES). All experiments were performed in triplicate. Data was analysed with two-way ANOVA and Student-Newman-Keuls post-hoc test. RESULTS: The release of nickel correlated to the wire type (p=0, 025 ; η2=0, 263), but not to the pH value. The NiTi wire released significantly less nickel at pH value 6.6 (p=0, 018 ; η2=0, 698). The release of titanium correlated to the wire type (p<0, 001 ; η2=0, 801) and the pH value (p<0, 001 ; η2=0, 633). The RhNiTi wire released significantly less titanium at pH value 6.6 (p=0, 004 ; η2=0, 798). CONCLUSIONS: Coating on the wire surface modifies the release of ions from nickel-titanium wires in artificial saliva with different acidity. The release of titanium depends on acidity level of artificial saliva.
Izvorni jezik
Engleski
Znanstvena područja
Kemijsko inženjerstvo, Dentalna medicina
Napomena
Izrađeno i financirano u sklopu projekta “Imunosne i regenerativne implikacije korozije dentalnih materijala u djece i adolescenata” Hrvatske zaklade za znanost (IP-2014-09-7500) voditelja Stjepana Špalja
POVEZANOST RADA
Projekti:
HRZZ-IP-2014-09-7500 - Imunosne i regenerativne implikacije korozije dentalnih materijala u djece i adolescenata (IMUNODENT) (Špalj, Stjepan) ( CroRIS)
Ustanove:
INA-Industrija nafte d.d.,