Energy dependence characteristics of new TLDs in terms of Hp(10) values.
Energy dependence characteristics of new TLDs in terms of Hp(10) values. // Towards Harmonisation of Radiation Protection in Europe - Book of Abstracts / D'Alberti, Francesco; Osimani, Celso (ur.).
Firenza : München: AIRP, IRPA, EC, 2002. str. P253-249 (poster, nije recenziran, sažetak, znanstveni)
CROSBI ID: 82163 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Energy dependence characteristics of new TLDs in terms of Hp(10) values.
Autori
Miljanić, Saveta ; Knežević, Željka ; Krpan, Katarina ; Štuhec, Matjaž ; Vekić, Branko ; Ranogajec-Komor, Maria
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Towards Harmonisation of Radiation Protection in Europe - Book of Abstracts
/ D'Alberti, Francesco; Osimani, Celso - Firenza : München : AIRP, IRPA, EC, 2002, P253-249
Skup
European IRPA Congress 2002 - Towards Harmonisation of Radiation Protection in Europe
Mjesto i datum
Firenca, Italija, 08.10.2002. - 11.10.2002
Vrsta sudjelovanja
Poster
Vrsta recenzije
Nije recenziran
Sažetak
In our previous work, the energy dependence characteristics for several types of the most interesting “tissue-equivalent” thermoluminescent detectors (TLDs) were investigated. Irradiations were performed “in air” and energy dependence was determinated as a characteristic of the TL detector material itself. The aim of this work was to determine energy dependence characteristics in terms of the personal dose equivalent Hp(10) values. For this reason detectors during the irradiation were placed on the adequate phantom. The following types of TLDs were investigated: a) two new types based on lithium borate: Li2B4O7:Cu,In and Li2B4O7:Cu,In,Ag; b) two types of the highly sensitive LiF:Mg,Cu,P material: TLD-700H and GR 200A, c) two well known types of LiF:Mg,Ti detectors: TLD-100 and TLD-700 and d) the highly sensitive Al2O3:C detectors. TLDs previously calibrated with 137Cs gamma rays, were simultaneously irradiated with X ray beams in the range of effective energies between 33 and 116 keV. The irradiations were performed with detectors in PMMA holders placed on the 30 cm x 30 cm x 15 cm water phantom with PMMA walls (ISO phantom). Measured energy responses were compared with calculated data for Hp(10) values. The results confirmed the good tissue equivalence characteristics of the lithium borate based detectors. Also, it was shown that the calibration procedure must be adjusted according to the energy absorption characteristics of the individual dosemeter type.
Izvorni jezik
Engleski
Znanstvena područja
Kemija