Radiation protection and dose measurements during the operation of reloading of 3.41 PBq 60Co sources.


Vekić, Branko; Ražem, Dušan; Ranogajec, Franjo; Miljanić, Saveta; Blažević, Milan
Radiation protection and dose measurements during the operation of reloading of 3.41 PBq 60Co sources. // Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health, Dubrovnik, 21.-25.5.2001. / Obelić, B.; Ranogajec-Komor, M.; Miljanić, S.; Krajcar Bronić, I (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2002. str. 7p-12 (poster, nije recenziran, sažetak, znanstveni)


CROSBI ID: 82148 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Radiation protection and dose measurements during the operation of reloading of 3.41 PBq 60Co sources.

Autori
Vekić, Branko ; Ražem, Dušan ; Ranogajec, Franjo ; Miljanić, Saveta ; Blažević, Milan

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health, Dubrovnik, 21.-25.5.2001. / Obelić, B.; Ranogajec-Komor, M.; Miljanić, S.; Krajcar Bronić, I - Zagreb : Hrvatsko društvo za zaštitu od zračenja, 2002, 7p-12

Skup
IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health

Mjesto i datum
Dubrovnik, Hrvatska, 20.05.2001. - 25.05.2001

Vrsta sudjelovanja
Poster

Vrsta recenzije
Nije recenziran

Sažetak
The panoramic 60Co irradiation facility at the Ruđer Bošković Institute is suitable for a variety of applications: from medium doses used in radiobiology to high doses pertaining to radiation processing and radiation chemistry research. It was designed and constructed to provide maximum flexibility with respect to dose rate. The irradiation source itself is formed by 24 source assemblies arranged in a cylinder, 26 cm in diameter. In February 1983 1.85 PBq of 60Co, produced in the USSR, in the form of 48 pencils were loaded in 12 source holders, 4 pencils in each holder. In June 1991 additional 3.5 PBq of 60Co in the form of 42 pencils were loaded in 12 source holders, 6 holders containing 4 pencils and 6 holders containing 3 pencils. Due to the decrease of 60Co activity 12 source holders installed in 1983 had to be exchanged and new sources installed. In June 2000 new 3.41 PBq of 60Co, in the form of 48 pencils were received by the Ruđer Bošković Institute. We had first to unload 12 source holders (186.5 TBq) installed in 1983 and after that to load the new 48 sources (3.41 PBq) into the irradiator. So the irradiator reached its maximum rated activity (4.42 PBq). The radiation protection measures during unloading of old sources and loading of the new ones are described in detail. All operations were planned in advance. Lessons learned during the two previous loading operations were analysed and taken into account. Necessary technical and organisational improvements were made. All personnel were trained in accordance with the previously prepared scenario, in which each operation was described and the person designated to carry out that operation was defined, as well as the person supervising that particular operation. The highest whole body dose during the exchange of sources was 0.42 mSv.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
00980904
00980905

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Franjo Ranogajec (autor)

Avatar Url Saveta Miljanić (autor)

Avatar Url Dušan Ražem (autor)

Avatar Url Branko Vekić (autor)


Citiraj ovu publikaciju:

Vekić, Branko; Ražem, Dušan; Ranogajec, Franjo; Miljanić, Saveta; Blažević, Milan
Radiation protection and dose measurements during the operation of reloading of 3.41 PBq 60Co sources. // Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health, Dubrovnik, 21.-25.5.2001. / Obelić, B.; Ranogajec-Komor, M.; Miljanić, S.; Krajcar Bronić, I (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2002. str. 7p-12 (poster, nije recenziran, sažetak, znanstveni)
Vekić, B., Ražem, D., Ranogajec, F., Miljanić, S. & Blažević, M. (2002) Radiation protection and dose measurements during the operation of reloading of 3.41 PBq 60Co sources.. U: Obelić, B., Ranogajec-Komor, M., Miljanić, S. & Krajcar Bronić, I. (ur.)Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health, Dubrovnik, 21.-25.5.2001..
@article{article, author = {Veki\'{c}, Branko and Ra\v{z}em, Du\v{s}an and Ranogajec, Franjo and Miljani\'{c}, Saveta and Bla\v{z}evi\'{c}, Milan}, year = {2002}, pages = {7p-12}, keywords = {}, title = {Radiation protection and dose measurements during the operation of reloading of 3.41 PBq 60Co sources.}, keyword = {}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Dubrovnik, Hrvatska} }
@article{article, author = {Veki\'{c}, Branko and Ra\v{z}em, Du\v{s}an and Ranogajec, Franjo and Miljani\'{c}, Saveta and Bla\v{z}evi\'{c}, Milan}, year = {2002}, pages = {7p-12}, keywords = {}, title = {Radiation protection and dose measurements during the operation of reloading of 3.41 PBq 60Co sources.}, keyword = {}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Dubrovnik, Hrvatska} }