Pregled bibliografske jedinice broj: 82143
Response of new TLDs to medium and low energy X-rays.
Response of new TLDs to medium and low energy X-rays. // Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health, Dubrovnik, 20.-25.5.2001. / Obelić, B.; Ranogajec-Komor, M.; Miljanić, S.; Krajcar Bronić, I (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2002. str. 7p-09 (poster, nije recenziran, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 82143 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Response of new TLDs to medium and low energy X-rays.
Autori
Knežević, Željka ; Miljanić, Saveta ; Ranogajec-Komor, Maria ; Vekić, Branko ; Štuhec, Matjaž ; Lakovič, Gorazd ; Martinčič, Rafael
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health, Dubrovnik, 20.-25.5.2001.
/ Obelić, B.; Ranogajec-Komor, M.; Miljanić, S.; Krajcar Bronić, I - Zagreb : Hrvatsko društvo za zaštitu od zračenja, 2002, 7p-09
Skup
IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health
Mjesto i datum
Dubrovnik, Hrvatska, 20.05.2001. - 25.05.2001
Vrsta sudjelovanja
Poster
Vrsta recenzije
Nije recenziran
Ključne riječi
TLD; energy dependence; LiF:Mg;Cu;P; Li2B4O7
Sažetak
In order to determine the energy response characteristics, several types of TLDs previously calibrated with 137Cs gamma rays, were irradiated with X-ray beams in the range of effective energies between 33 and 116 keV. The following types of TLDs were investigated: two types of the recently developed highly sensitive LiF:Mg,Cu,P material: TLD-700H and GR 200A, two new types on the basis of lithium borate: Li2B4O7:Cu,In and Li2B4O7:Cu,In,Ag (developed in the Institute of Nuclear Science, Vinča), two well known types of LiF:Mg,Ti detectors: TLD-100 and TLD-700 and the new, highly sensitive Al2O3:C. Measured energy responses relative to air, normalised to 137Cs photons were compared with calculated data. Although the deviations of the measured data from the “theoretical” predictions are different for all investigated TLDs, there are no large differences in “tissue equivalency” between them. The only exception is Al2O3:C, which (due to large energy dependence) is not suitable for personal dosimetry in an unknown photon radiation field.
Izvorni jezik
Engleski
Znanstvena područja
Kemija
POVEZANOST RADA
Projekti:
00980904
Ustanove:
Institut "Ruđer Bošković", Zagreb
Profili:
Željka Knežević Medija
(autor)
Saveta Miljanić
(autor)
Ferencne Ranogajec
(autor)
Branko Vekić
(autor)