Pregled bibliografske jedinice broj: 813941
Mechanical testing of orthodontic archwires
Mechanical testing of orthodontic archwires // Proceedings of the 16th EUSPEN International Conference / Bointon, P. ; Leach, R. ; Southon, N. (ur.).
Cranfield: European Society for Precision Engineering and Nanotechnology (EUSPEN), 2016. str. 339-340 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 813941 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Mechanical testing of orthodontic archwires
Autori
Katić, Višnja ; Zelenika, Saša ; Kamenar, Ervin ; Marković, Kristina ; Perčić, Marko ; Špalj, Stjepan
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 16th EUSPEN International Conference
/ Bointon, P. ; Leach, R. ; Southon, N. - Cranfield : European Society for Precision Engineering and Nanotechnology (EUSPEN), 2016, 339-340
ISBN
978-0-9566790-8-6
Skup
16th EUSPEN International Conference
Mjesto i datum
Nottingham, Ujedinjeno Kraljevstvo, 30.05.2016. - 03.06.2016
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Nickel-titanium archwires ; coating and corrosion ; AFM and nanoindentation testing ; surface roughness ; hardness ; Young’s modulus
Sažetak
Mechanical properties of orthodontic archwires are studied in this work in the micrometric domain. Measurements are performed on nickel- titanium archwires without and with different coatings as well as subjected for four weeks to an artificial saliva solution with different pH values (4.8 and 6.6). Since surface properties can have a meaningful influence on friction, corrosion or plaque accumulation, surface texture of the wires is measured by employing atomic force microscopy. On the other hand, with the aim of determining Young’s modulus and the hardness, nanoindentation tests are performed for different peak load values. It is hence established that there is no statistically relevant deterioration of the surfaces after their exposure to saliva. Rh coating leads, in turn, to an increase of surface roughness. Young’s moduli and hardness values tend to increase with increasing indentation depths, while they are not meaningfully affected by the coating or the corrosion in saliva.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo, Temeljne tehničke znanosti, Interdisciplinarne tehničke znanosti, Dentalna medicina
Napomena
Izrađeno i financirano u sklopu projekta
“Imunosne i regenerativne implikacije korozije
dentalnih materijala u djece i adolescenata”
Hrvatske zaklade za znanost (IP-2014-09-7500)
voditelja Stjepana Špalja
POVEZANOST RADA
Projekti:
--IP-2014-09-7500 - Imunosne i regenerativne implikacije korozije dentalnih materijala u djece i adolescenata (IMUNODENT) (Špalj, Stjepan) ( CroRIS)
Ustanove:
Medicinski fakultet, Rijeka,
Tehnički fakultet, Rijeka,
Sveučilište u Rijeci
Profili:
Marko Perčić
(autor)
Višnja Katić
(autor)
Ervin Kamenar
(autor)
Stjepan Špalj
(autor)
Saša Zelenika
(autor)
Kristina Marković
(autor)