Energy and Angular dependence of Radiophotoluminescence Glass Dosemeters for Eye Lens Dosimetry


Silva, E. H.; Knežević, Željka; Struelens, L.; Covens, P.; Ueno, S.; Vanhavere, F.; Buls, N.
Energy and Angular dependence of Radiophotoluminescence Glass Dosemeters for Eye Lens Dosimetry // Radiation protection dosimetry, 170 (2016), 1-4; 208-212 doi:10.1093/rpd/ncw104 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 808766 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Energy and Angular dependence of Radiophotoluminescence Glass Dosemeters for Eye Lens Dosimetry

Autori
Silva, E. H. ; Knežević, Željka ; Struelens, L. ; Covens, P. ; Ueno, S. ; Vanhavere, F. ; Buls, N.

Izvornik
Radiation protection dosimetry (0144-8420) 170 (2016), 1-4; 208-212

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
radiophotoluminescence glass dosimetry ; RPL ; energy dependence ; angular dependence ; eye lens dosimetry

Sažetak
Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection (ICRP) recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y down to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radiophotoluminescent (RPL) glass dosemeters (GD-300 series – ATGC Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0° up to 90°, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK•CEN – Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruđer Bošković Institute – Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to SCs, on the cylindrical phantom. From 0° up to 45°, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low energy photons (N-60). Results showed that GD-300 series have good properties related to Hp(3), although some improvements may be necessary.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kemija



POVEZANOST RADA


Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Željka Knežević Medija (autor)

Poveznice na cjeloviti tekst rada:

doi academic.oup.com doi.org

Citiraj ovu publikaciju:

Silva, E. H.; Knežević, Željka; Struelens, L.; Covens, P.; Ueno, S.; Vanhavere, F.; Buls, N.
Energy and Angular dependence of Radiophotoluminescence Glass Dosemeters for Eye Lens Dosimetry // Radiation protection dosimetry, 170 (2016), 1-4; 208-212 doi:10.1093/rpd/ncw104 (međunarodna recenzija, članak, znanstveni)
Silva, E., Knežević, Ž., Struelens, L., Covens, P., Ueno, S., Vanhavere, F. & Buls, N. (2016) Energy and Angular dependence of Radiophotoluminescence Glass Dosemeters for Eye Lens Dosimetry. Radiation protection dosimetry, 170 (1-4), 208-212 doi:10.1093/rpd/ncw104.
@article{article, author = {Silva, E. H. and Kne\v{z}evi\'{c}, \v{Z}eljka and Struelens, L. and Covens, P. and Ueno, S. and Vanhavere, F. and Buls, N.}, year = {2016}, pages = {208-212}, DOI = {10.1093/rpd/ncw104}, keywords = {radiophotoluminescence glass dosimetry, RPL, energy dependence, angular dependence, eye lens dosimetry}, journal = {Radiation protection dosimetry}, doi = {10.1093/rpd/ncw104}, volume = {170}, number = {1-4}, issn = {0144-8420}, title = {Energy and Angular dependence of Radiophotoluminescence Glass Dosemeters for Eye Lens Dosimetry}, keyword = {radiophotoluminescence glass dosimetry, RPL, energy dependence, angular dependence, eye lens dosimetry} }
@article{article, author = {Silva, E. H. and Kne\v{z}evi\'{c}, \v{Z}eljka and Struelens, L. and Covens, P. and Ueno, S. and Vanhavere, F. and Buls, N.}, year = {2016}, pages = {208-212}, DOI = {10.1093/rpd/ncw104}, keywords = {radiophotoluminescence glass dosimetry, RPL, energy dependence, angular dependence, eye lens dosimetry}, journal = {Radiation protection dosimetry}, doi = {10.1093/rpd/ncw104}, volume = {170}, number = {1-4}, issn = {0144-8420}, title = {Energy and Angular dependence of Radiophotoluminescence Glass Dosemeters for Eye Lens Dosimetry}, keyword = {radiophotoluminescence glass dosimetry, RPL, energy dependence, angular dependence, eye lens dosimetry} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font