Pregled bibliografske jedinice broj: 793918
Radiation doses on CT scanner in UH Rijeka and comparison with European Commision dose reference levels
Radiation doses on CT scanner in UH Rijeka and comparison with European Commision dose reference levels // Proceedings of the ninth symposium of the CRPA
Krk, Hrvatska: Hrvatsko društvo za zaštitu od zračenja, 2013. str. 259-264 (predavanje, domaća recenzija, cjeloviti rad (in extenso), stručni)
CROSBI ID: 793918 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Radiation doses on CT scanner in UH Rijeka and comparison with European Commision dose reference levels
Autori
Šegota, Doris ; Jurković, Slaven ; Posedel, Dario ; Kralik, Ivana ; Miletić, Damir ; Faj, Dario
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni
Izvornik
Proceedings of the ninth symposium of the CRPA
/ - : Hrvatsko društvo za zaštitu od zračenja, 2013, 259-264
ISBN
978-953-96133-8-7
Skup
Deveti simpozij Hrvatskog društva za zaštitu od zračenja
Mjesto i datum
Krk, Hrvatska, 10.04.2013. - 12.04.2013
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Domaća recenzija
Ključne riječi
computed tomography ; dosimetry
Sažetak
The purpose of this study was to compare values of Local Diagnostic Reference Levels (LDRLs) of CT examination protocols used in UH Rijeka with European Commission (EC) Diagnostic Reference Dose Levels (DRLs) and to estimate patient effective dose per type of examination. The dosimetric quantities proposed for DRLs in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDIw) for a single slice and DLP for a complete examination. Patient’s data (weight, height) as well as technical parameters for each type of examination were collected on Siemens Sensation 16 CT scanner installed at Radiology Department, UH Rijeka. Examinations were categorized according to anatomy: brain, chest, abdomen and pelvis. Computed tomography dose index (CTDI) measurements were performed in CTDI phantom to assure readings accuracy. Both values, CTDIw and DLP, for all four examinations were within proposed values given by European Commission. Also, estimations of effective dose to the average patient for every type of CT examination were made. Results confirmed that UH Rijeka meets EC DRLs for all examinations.
Izvorni jezik
Engleski
Znanstvena područja
Temeljne medicinske znanosti, Kliničke medicinske znanosti