Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 775378

Articular-eminence Measurements Performed by Conventional and Three-dimensional Method


Kranjčić, Josip; Šlaus, Mario; Čatlak, Zlatko; Peršić, Sanja; Vojvodić, Denis
Articular-eminence Measurements Performed by Conventional and Three-dimensional Method // 39th annual conference of the European Prosthodontic Association
Prag: Czech Society of Prosthetic Dentistry and Czech Dental Chamber, 2015. str. 106-106 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 775378 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Articular-eminence Measurements Performed by Conventional and Three-dimensional Method
(Articular-eminence measurements performed by conventional and three-dimensional method)

Autori
Kranjčić, Josip ; Šlaus, Mario ; Čatlak, Zlatko ; Peršić, Sanja ; Vojvodić, Denis

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
39th annual conference of the European Prosthodontic Association / - Prag : Czech Society of Prosthetic Dentistry and Czech Dental Chamber, 2015, 106-106

ISBN
978-80-260-8581-2

Skup
39th Annual Conference of the European Prosthodontic Association

Mjesto i datum
Prag, Češka Republika, 03.09.2015. - 05.09.2015

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
articular-eminence Inclination ; three-dimensional method of measurement
(articular-eminence inclination ; three-dimensional method of measurement)

Sažetak
Purpose Articular eminence (AE) morphology could be expressed by dimensions and angles measured by different methods. The aim of this study was to compare conventional two-dimensional with three- dimensional laser method. Materials and Methods The study was carried out on 20 human dry skulls (18 to 65 years) from medieval and contemporary period. Measurements were performed on sections (real and virtual) through the AE silicone impressions (lateral-medial) using two-dimensional and three-dimensional (laser) digitalization. AE inclination (two methods) in relation to the Frankfurt horizontal, AE height and the length of curved line (highest to the lowest AE point) were measured. Results were statistically analyzed with significance level of 0.05. Results Although small differences existed between AE measurements performed by conventional and three-dimensional laser technology, most of obtained differences were not statistically significant (p values: AE inclination 0.003 to 1.0 ; AE height 0.012 to 1.0 ; curved line length of 0.115 to 1.0). Differences between AE inclination values measured by “best fit line” method and “fossa roof – eminence top” method were statistically significant (p<0.001). Conclusions Silicone impressions eased the procedure and retained accuracy for AE measurements. Differences for most of the performed measurements by conventional and three- dimensional method were not significant, thus indicating same reliability of the used methods. AE values by „best fit line“ method were higher than by „fossa roof–eminence top“ method no matter which measuring method was used. These values are more affected by the eminence height thus representing simplified but actual condylar path significant for adjustment of articulators.

Izvorni jezik
Engleski

Znanstvena područja
Dentalna medicina



POVEZANOST RADA


Projekti:
MZOS-065-0650445-0413 - Istraživanje materijala i kliničkih postupaka u stomatološkoj protetici (Vojvodić, Denis, MZOS ) ( CroRIS)
MZOS-065-0650446-0420 - Utjecaj protetskog rada i drugih faktora na stomatognati sustav i zdravlje (Čelebić, Asja, MZOS ) ( CroRIS)

Ustanove:
Stomatološki fakultet, Zagreb,
Hrvatska akademija znanosti i umjetnosti,
Klinička bolnica "Dubrava",
Klinički bolnički centar Zagreb

Poveznice na cjeloviti tekst rada:

www.protetickaspolecnost.cz

Citiraj ovu publikaciju:

Kranjčić, Josip; Šlaus, Mario; Čatlak, Zlatko; Peršić, Sanja; Vojvodić, Denis
Articular-eminence Measurements Performed by Conventional and Three-dimensional Method // 39th annual conference of the European Prosthodontic Association
Prag: Czech Society of Prosthetic Dentistry and Czech Dental Chamber, 2015. str. 106-106 (poster, međunarodna recenzija, sažetak, znanstveni)
Kranjčić, J., Šlaus, M., Čatlak, Z., Peršić, S. & Vojvodić, D. (2015) Articular-eminence Measurements Performed by Conventional and Three-dimensional Method. U: 39th annual conference of the European Prosthodontic Association.
@article{article, author = {Kranj\v{c}i\'{c}, Josip and \v{S}laus, Mario and \v{C}atlak, Zlatko and Per\v{s}i\'{c}, Sanja and Vojvodi\'{c}, Denis}, year = {2015}, pages = {106-106}, keywords = {articular-eminence Inclination, three-dimensional method of measurement}, isbn = {978-80-260-8581-2}, title = {Articular-eminence Measurements Performed by Conventional and Three-dimensional Method}, keyword = {articular-eminence Inclination, three-dimensional method of measurement}, publisher = {Czech Society of Prosthetic Dentistry and Czech Dental Chamber}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }
@article{article, author = {Kranj\v{c}i\'{c}, Josip and \v{S}laus, Mario and \v{C}atlak, Zlatko and Per\v{s}i\'{c}, Sanja and Vojvodi\'{c}, Denis}, year = {2015}, pages = {106-106}, keywords = {articular-eminence inclination, three-dimensional method of measurement}, isbn = {978-80-260-8581-2}, title = {Articular-eminence measurements performed by conventional and three-dimensional method}, keyword = {articular-eminence inclination, three-dimensional method of measurement}, publisher = {Czech Society of Prosthetic Dentistry and Czech Dental Chamber}, publisherplace = {Prag, \v{C}e\v{s}ka Republika} }




Contrast
Increase Font
Decrease Font
Dyslexic Font