Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 763286

Center of Gravity (COG) Method as a Tool in Processing of Voltammetric Signals


Jović, Ozren; Omanović, Dario; Zelić, Marina; Pižeta, Ivanka
Center of Gravity (COG) Method as a Tool in Processing of Voltammetric Signals // Electroanalysis, 27 (2015), 10; 2347-2356 doi:10.1002/elan.201500065 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 763286 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Center of Gravity (COG) Method as a Tool in Processing of Voltammetric Signals

Autori
Jović, Ozren ; Omanović, Dario ; Zelić, Marina ; Pižeta, Ivanka

Izvornik
Electroanalysis (1040-0397) 27 (2015), 10; 2347-2356

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
center of gravity; voltammetry; derivatives; metal complexation; stability constants

Sažetak
The center of gravity method (COG) was applied (for the first time) in voltammetry (polarography) as a tool for very precise determination of peak potentials, and signal shifts. Basically, the adjustment of the method consists of finding the optimal fraction of the peak that contains information about peak position, either of original signal or of its 1st or 2nd derivatives, along with optimal selection of parameters for Savitzky-Golay smoothing of original curves and elimination of baseline influence. The principle of the method and its validation were demonstrated and checked on simulated differential pulse polarograms (DPP) representing a series of curves for the determination of stability constants of labile metal complexes (DeFord-Hume method). It was shown that COG outperforms the classical “one-point” method (OPM) in precision and accuracy, providing excellent results even if a very large step potential (e.g. 10 mV) was used. The problems of reduced accuracy and precision in case of curved (non-ideal) baseline and asymmetric peaks were successfully overcome by applying COG on curves transformed by 1st and/or 2nd derivatives. The method was additionally examined in details on a simple experimental dataset of cadmium chloride complexes in 4 mol dm−3 ionic strength solution and on a more complex dataset of uranyl selenate complexes in 3 mol dm−3 ionic strength solution. Stability constants obtained by COG agree well with those in the literature with much better precision than the classical one-point method (checked by standard error of the fit).

Izvorni jezik
Engleski

Znanstvena područja
Geologija, Kemija



POVEZANOST RADA


Projekti:
098-0982934-2720 - Međudjelovanja oblika tragova metala u vodenom okolišu (Pižeta, Ivanka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb,
Prirodoslovno-matematički fakultet, Zagreb

Profili:

Avatar Url Ozren Jović (autor)

Avatar Url Dario Omanović (autor)

Avatar Url Marina Zelić (autor)

Avatar Url Ivanka Pižeta (autor)

Poveznice na cjeloviti tekst rada:

doi onlinelibrary.wiley.com onlinelibrary.wiley.com

Citiraj ovu publikaciju:

Jović, Ozren; Omanović, Dario; Zelić, Marina; Pižeta, Ivanka
Center of Gravity (COG) Method as a Tool in Processing of Voltammetric Signals // Electroanalysis, 27 (2015), 10; 2347-2356 doi:10.1002/elan.201500065 (međunarodna recenzija, članak, znanstveni)
Jović, O., Omanović, D., Zelić, M. & Pižeta, I. (2015) Center of Gravity (COG) Method as a Tool in Processing of Voltammetric Signals. Electroanalysis, 27 (10), 2347-2356 doi:10.1002/elan.201500065.
@article{article, author = {Jovi\'{c}, Ozren and Omanovi\'{c}, Dario and Zeli\'{c}, Marina and Pi\v{z}eta, Ivanka}, year = {2015}, pages = {2347-2356}, DOI = {10.1002/elan.201500065}, keywords = {center of gravity, voltammetry, derivatives, metal complexation, stability constants}, journal = {Electroanalysis}, doi = {10.1002/elan.201500065}, volume = {27}, number = {10}, issn = {1040-0397}, title = {Center of Gravity (COG) Method as a Tool in Processing of Voltammetric Signals}, keyword = {center of gravity, voltammetry, derivatives, metal complexation, stability constants} }
@article{article, author = {Jovi\'{c}, Ozren and Omanovi\'{c}, Dario and Zeli\'{c}, Marina and Pi\v{z}eta, Ivanka}, year = {2015}, pages = {2347-2356}, DOI = {10.1002/elan.201500065}, keywords = {center of gravity, voltammetry, derivatives, metal complexation, stability constants}, journal = {Electroanalysis}, doi = {10.1002/elan.201500065}, volume = {27}, number = {10}, issn = {1040-0397}, title = {Center of Gravity (COG) Method as a Tool in Processing of Voltammetric Signals}, keyword = {center of gravity, voltammetry, derivatives, metal complexation, stability constants} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font