Experimental performance analysis of an integrated air-conditioning split heat pump system for application in a Mediterranean climate


Nižetić, Sandro; Onder, Kizilkan; Čoko, Duje
Experimental performance analysis of an integrated air-conditioning split heat pump system for application in a Mediterranean climate // International Exergy, Energy and Environment Symposium / Fethi, Aloui (ur.).
Valenciennes, 2015. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 760242 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Experimental performance analysis of an integrated air-conditioning split heat pump system for application in a Mediterranean climate

Autori
Nižetić, Sandro ; Onder, Kizilkan ; Čoko, Duje

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
International Exergy, Energy and Environment Symposium / Fethi, Aloui - Valenciennes, 2015

ISBN
978-2-36424-030-8

Skup
7th International. Exergy, Energy and Environment Symposium

Mjesto i datum
Valenciennes, Francuska, 27.04.2015. - 30.04.2015

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Heat pump; experimental investigation; photovoltaics; performance analysis; energy efficiency

Sažetak
In this paper an experimental setup of an integrated air-conditioning split heat pump system is elaborated in detail together with a performance analysis. The proposed energy system consists of a standard split air- conditioning device, boiler for hot water preparation where the whole system is driven by a small photovoltaic plant. The energy system was tested in a cooling and heating regime in a location with a typical Mediterranean climate to determine the average performance parameters. The main goal of the conducted research was to utilize existing market available energy technologies that can be found in majority of building applications being residential or commercial ones, in the form of a modified (hybrid) energy system. The performance analysis shows a market potential for the proposed energy solution as it is suitable from the aspect of energy efficiency and also presents a renewable energy system that can be easily implemented into building applications. Namely, the average COP value was 5.3 for heating mode and 5.4 for cooling mode, the mean electricity consumption ranged from 0.55 kWh up to 1.14 kWh, the mean water temperature ranged from 42°C to 46°C and finally the PV system autonomy ranged from 6 h in winter operation up to 12 h in summer operation. In general, cooling mode was more efficient regarding achieved performance parameters.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne tehničke znanosti



POVEZANOST RADA


Ustanove:
Fakultet elektrotehnike, strojarstva i brodogradnje, Split

Profili:

Avatar Url Duje Čoko (autor)

Avatar Url Sandro Nižetić (autor)


Citiraj ovu publikaciju:

Nižetić, Sandro; Onder, Kizilkan; Čoko, Duje
Experimental performance analysis of an integrated air-conditioning split heat pump system for application in a Mediterranean climate // International Exergy, Energy and Environment Symposium / Fethi, Aloui (ur.).
Valenciennes, 2015. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Nižetić, S., Onder, K. & Čoko, D. (2015) Experimental performance analysis of an integrated air-conditioning split heat pump system for application in a Mediterranean climate. U: Fethi, A. (ur.)International Exergy, Energy and Environment Symposium.
@article{article, author = {Ni\v{z}eti\'{c}, Sandro and Onder, Kizilkan and \v{C}oko, Duje}, editor = {Fethi, A.}, year = {2015}, keywords = {Heat pump, experimental investigation, photovoltaics, performance analysis, energy efficiency}, isbn = {978-2-36424-030-8}, title = {Experimental performance analysis of an integrated air-conditioning split heat pump system for application in a Mediterranean climate}, keyword = {Heat pump, experimental investigation, photovoltaics, performance analysis, energy efficiency}, publisherplace = {Valenciennes, Francuska} }
@article{article, author = {Ni\v{z}eti\'{c}, Sandro and Onder, Kizilkan and \v{C}oko, Duje}, editor = {Fethi, A.}, year = {2015}, keywords = {Heat pump, experimental investigation, photovoltaics, performance analysis, energy efficiency}, isbn = {978-2-36424-030-8}, title = {Experimental performance analysis of an integrated air-conditioning split heat pump system for application in a Mediterranean climate}, keyword = {Heat pump, experimental investigation, photovoltaics, performance analysis, energy efficiency}, publisherplace = {Valenciennes, Francuska} }