Pregled bibliografske jedinice broj: 752173
Provjera računa apsorbirane doze u XiO računalnom sustavu za planiranje radioterapije
Provjera računa apsorbirane doze u XiO računalnom sustavu za planiranje radioterapije // Proceedings of the ninth symposium of the Croatian Radiation Protection Association / Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2013. str. 93-98 (predavanje, domaća recenzija, cjeloviti rad (in extenso), stručni)
CROSBI ID: 752173 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Provjera računa apsorbirane doze u XiO računalnom sustavu za planiranje radioterapije
(Verification of absorbed dose calculation with XiO treatment planning system)
Autori
Mlinarić, Mihaela ; Budanec, Mirjana ; Mrčela, Iva ; Gregov, Marin ; Bokulić, Tomislav ; Kusić, Zvonko
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni
Izvornik
Proceedings of the ninth symposium of the Croatian Radiation Protection Association
/ Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines - Zagreb : Hrvatsko društvo za zaštitu od zračenja, 2013, 93-98
ISBN
978-953-96133-8-7
Skup
9th symposium of the Croatian Radiation Protection Association with international participation
Mjesto i datum
Krk, Hrvatska, 10.04.2013. - 12.04.2013
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Domaća recenzija
Ključne riječi
verifikacija; račun doze; TPS
(TPS; dose calculation; verification)
Sažetak
Modern radiotherapy relies on computeri z ed treatment planning systems (TPS) for absorbed dose calculation. Most TPS require a detailed model of a given machine and therapy beams. International Atomic Energy Agency (IAEA) recommends acceptance testing for the TPS (IAEA - TECDOC - 1540). In this study we present customization of those tests for measurements with the purpose of verification of beam models intended for clinical use in our department. Elekta Synergy S linear accelerator installation and data acquisition for Elekta CMS XiO 4.62 TPS was finished in 2011 . After the completion of beam modelling in TPS, tests were conducted in accordance with the IAEA protocol for TPS dose calculation verification. The d eviation s between the measured and calculated dose were recorded for 854 points and 11 groups of tests in a homogenous phantom. Most of the deviations were within tolerance. Similar to previously published results, results f or irregular L shaped field and asymmetric wedged fields were out of tolerance for certain groups of points
Izvorni jezik
Hrvatski
Znanstvena područja
Fizika
POVEZANOST RADA
Ustanove:
KBC "Sestre Milosrdnice"
Profili:
Mirjana Budanec
(autor)
Zvonko Kusić
(autor)
Tomislav Bokulić
(autor)
Mihaela Mlinarić
(autor)
Iva Mrčela
(autor)