Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 752171

Mjerenje neutronskih i fotonskih brzina okolišnih ekvivalentnih doza u radioterapiji


Gregov, Marin; Bokulić, Tomislav; Mlinarić Mihaela; Mrčela, Iva; Budanec, Mirjana; Prlić, Ivica; Kusić, Zvonko
Mjerenje neutronskih i fotonskih brzina okolišnih ekvivalentnih doza u radioterapiji // Proceedings of the ninth symposium of the Croatian Radiation Protection Association / Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2013. str. 314-320 (predavanje, domaća recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 752171 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Mjerenje neutronskih i fotonskih brzina okolišnih ekvivalentnih doza u radioterapiji
(Measurement of neutron and photon ambient equivalent dose rates in radiotherapy)

Autori
Gregov, Marin ; Bokulić, Tomislav ; Mlinarić Mihaela ; Mrčela, Iva ; Budanec, Mirjana ; Prlić, Ivica ; Kusić, Zvonko

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the ninth symposium of the Croatian Radiation Protection Association / Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines - Zagreb : Hrvatsko društvo za zaštitu od zračenja, 2013, 314-320

ISBN
978-953-96133-8-7

Skup
9th symposium of the Croatian Radiation Protection Association with international participation

Mjesto i datum
Krk, Hrvatska, 10.04.2013. - 12.04.2013

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Domaća recenzija

Ključne riječi
neutronska okolišna ekvivalentna brzina doze; radioterapija
(neutron ambient equivalent dose rate; radiotherapy)

Sažetak
In radiotherapy with linear accelerator, for photon beam energies higher than 10 MV, secondary neutrons and their associated photons are significantly produced in pho tonuclear reactions. In this work, measurements of neutron and photon ambient equivalent dose rates ( ) are car ried out inside and outside of the treatment room. Measurements were performed with the linear accelerator Elekta Synergy S, for 18 MV energy photon beams, with simulation of clinical conditions by placing the Alderson phantom on the pat ient table during all measurements. ( ) were measured with the neutron BF 3 detector Thermo FHT 752, proportional detector Thermo FHT 40G and ionization chamber Gamma - Dosimeter 27091 at a height of 1 m, at points inside the treatment room, along t he maze and around the accelerator, and also outside of the treatment room, in front of the door and in the control room. Results show that ( ) depends on the gantry angle, delivered number of monitor units and photon beam field size. During the t reatment, neutron dose rate is significantly higher than photon dose rate in all points of measurements except in the control room. Neutron and photon dose rates decrease with distance from the isocentre. Neutron dose rate depends also on the cross - section of inner entrance of the maze and cross - section of the maze. Effective dose to the staff is predicted from the results obtained

Izvorni jezik
Hrvatski

Znanstvena područja
Fizika



POVEZANOST RADA


Ustanove:
KBC "Sestre Milosrdnice"

Citiraj ovu publikaciju:

Gregov, Marin; Bokulić, Tomislav; Mlinarić Mihaela; Mrčela, Iva; Budanec, Mirjana; Prlić, Ivica; Kusić, Zvonko
Mjerenje neutronskih i fotonskih brzina okolišnih ekvivalentnih doza u radioterapiji // Proceedings of the ninth symposium of the Croatian Radiation Protection Association / Knežević, Željka ; Majer, Marija ; Krajcar Bronić, Ines (ur.).
Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2013. str. 314-320 (predavanje, domaća recenzija, cjeloviti rad (in extenso), znanstveni)
Gregov, M., Bokulić, T., Mlinarić Mihaela, Mrčela, I., Budanec, M., Prlić, I. & Kusić, Z. (2013) Mjerenje neutronskih i fotonskih brzina okolišnih ekvivalentnih doza u radioterapiji. U: Knežević, Ž., Majer, M. & Krajcar Bronić, I. (ur.)Proceedings of the ninth symposium of the Croatian Radiation Protection Association.
@article{article, author = {Gregov, Marin and Bokuli\'{c}, Tomislav and Mr\v{c}ela, Iva and Budanec, Mirjana and Prli\'{c}, Ivica and Kusi\'{c}, Zvonko}, year = {2013}, pages = {314-320}, keywords = {neutronska okoli\v{s}na ekvivalentna brzina doze, radioterapija}, isbn = {978-953-96133-8-7}, title = {Mjerenje neutronskih i fotonskih brzina okoli\v{s}nih ekvivalentnih doza u radioterapiji}, keyword = {neutronska okoli\v{s}na ekvivalentna brzina doze, radioterapija}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Krk, Hrvatska} }
@article{article, author = {Gregov, Marin and Bokuli\'{c}, Tomislav and Mr\v{c}ela, Iva and Budanec, Mirjana and Prli\'{c}, Ivica and Kusi\'{c}, Zvonko}, year = {2013}, pages = {314-320}, keywords = {neutron ambient equivalent dose rate, radiotherapy}, isbn = {978-953-96133-8-7}, title = {Measurement of neutron and photon ambient equivalent dose rates in radiotherapy}, keyword = {neutron ambient equivalent dose rate, radiotherapy}, publisher = {Hrvatsko dru\v{s}tvo za za\v{s}titu od zra\v{c}enja}, publisherplace = {Krk, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font