Pregled bibliografske jedinice broj: 740602
Influence of various factors on the dose of personnel during cardiology diagnostic
Influence of various factors on the dose of personnel during cardiology diagnostic // Proceedings of the Second International Conference on Radiation and Dosimetry in Various Fields of Research / Ristć, Goran (ur.).
Niš: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2014. str. 207-210 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 740602 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Influence of various factors on the dose of personnel during cardiology diagnostic
Autori
Milković, Đurđica ; Ranogajec-Komor, Mária ; Porcs-Makkay, László ; Knežević, Željka
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the Second International Conference on Radiation and Dosimetry in Various Fields of Research
/ Ristć, Goran - Niš : Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2014, 207-210
ISBN
978-86-6125-101-6
Skup
Second International Conference on Radiation and Dosimetry in Various Fields of Research
Mjesto i datum
Niš, Srbija, 27.05.2014. - 30.05.2014
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
coronarography; radiation protection; scattered radiation; RPL dosimetry
Sažetak
The aim of this work was the determination of staff exposure during coronary diagnostic procedure and the investigation of the effect of some factors (working method, fluoroscopy time, physical characteristics of cardiologist) on the doses to personnel. The measured doses in this work were compared to the doses measured by the National Dosimetry Service. The doses were measured with LiF:Mg, Cu, P thermoluminescence and phosphate glass radiophotoluminescence dosimetry systems (GD-352M) under and over the apron on the chest, on the left eye (eyebrow), left shoulder out of the apron, and left wrist of 3 cardiology doctors. Each doctor carried out 5 diagnostic coronary angiography procedures. The annual effective doses Eeff, calculated from the measured values as well as the equivalent doses to the eyes, were in all cases below the required dose limit (20 mSv/y ear). Significant differences of the effective doses were found among the three doctors in this study (15.5 mSv, 10.4 mSv, 8.7 mSv), as well as in the earlier results of the National Dosimetry Service (9.2 mSv, 4.6 mSv, 1.3 mSv). It was found that a single dosimeter under the apron performed by the National Service underestimates the Eeff as compared to the double dosimetry carried out in this study. The doses depend on many factors in coronary angiography, such as fluoroscopy time, complexity and number of examinations, experience of the doctor, feature of the doctor (height) and patient himself.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kemija, Kliničke medicinske znanosti
POVEZANOST RADA
Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)
Ustanove:
Institut "Ruđer Bošković", Zagreb,
Dječja bolnica Srebrnjak