Digital Dosemeter "ALARA OD 2 - ORT" Monitoring Assembly


Prlić, Ivica; Radalj, Željko; Vrtar, Mladen; Cerovac, Zdravko; Kovačević, Nenad; Gladić, Jadranko;
Digital Dosemeter "ALARA OD 2 - ORT" Monitoring Assembly // IRPA Regional Congress on Radiation Protection in Central Europe RADIATION PROTECTION AND HEALTH / Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I. (ur.).
Dubrovnik: MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,, 2001. str. 205-205 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 71906 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Digital Dosemeter "ALARA OD 2 - ORT" Monitoring Assembly

Autori
Prlić, Ivica ; Radalj, Željko ; Vrtar, Mladen ; Cerovac, Zdravko ; Kovačević, Nenad ; Gladić, Jadranko ;

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
IRPA Regional Congress on Radiation Protection in Central Europe RADIATION PROTECTION AND HEALTH / Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I. - Dubrovnik : MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,, 2001, 205-205

Skup
IPRA Regional Congres on Radiation Protection in Central Europe

Mjesto i datum
Dubrovnik, Hrvatska, 20.05.2001. - 25.05.2001

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
External Dosimetry; Digital dosemeters; Quality Assurance; Radiation Protection

Sažetak
New Croatian radiation protection law regulations are based, among other positive principles, on the principle of establishing the controlled area in which the workers undergo legal and obligatory external occupational dosimetry monitoring. Outside the area the 1 mSv/year level of exposure is not to be exceeded by the operating radiation source. “Ort” is the common name for the above mentioned “outside area” which is to be monitored. The new digital dosimeter device ALARA OD, produced by ALARA Instruments Ltd. has the probe sensitive to the background radiation and fast enough to record any change in normal environmental-background radiation field. If user or dosimeter device enter the higher radiation field area or radiation source produces higher radiation output, second mode will separately start to measure the dose which is at least two times higher than the background at the spot. This methodology of measurement was performed one year long with the set of 60 devices on more than 35 X-ray units used for the civil baggage control on the airports and else. The dosimeter device was a part of whole x-ray system, meaning that one device was always on the spot which was recommended from the manufacturer as a spot with highest external exposure possibilities if any at all. Devices integrated the radiation for the whole year (battery cap. 5 years) and the net result is that there is no need for obligatory dosimetry monitoring of the workers and other stuff working with or near such X-ray units because the integrated dose while X-ray units working on the full load did not exceed the 1 mSv/year level.

Izvorni jezik
Engleski

Znanstvena područja
Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekti:
00220205

Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb

Profili:

Avatar Url Ivica Prlić (autor)

Avatar Url Jadranko Gladić (autor)

Avatar Url Mladen Vrtar (autor)


Citiraj ovu publikaciju:

Prlić, Ivica; Radalj, Željko; Vrtar, Mladen; Cerovac, Zdravko; Kovačević, Nenad; Gladić, Jadranko;
Digital Dosemeter "ALARA OD 2 - ORT" Monitoring Assembly // IRPA Regional Congress on Radiation Protection in Central Europe RADIATION PROTECTION AND HEALTH / Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I. (ur.).
Dubrovnik: MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,, 2001. str. 205-205 (poster, međunarodna recenzija, sažetak, znanstveni)
Prlić, I., Radalj, Ž., Vrtar, M., Cerovac, Z., Kovačević, N., Gladić, J. & (2001) Digital Dosemeter "ALARA OD 2 - ORT" Monitoring Assembly. U: Obelić, B. Ranogajec-Komor, M., Miljanić, S. Krajcar Bronić, I. (ur.)IRPA Regional Congress on Radiation Protection in Central Europe RADIATION PROTECTION AND HEALTH.
@article{article, author = {Prli\'{c}, Ivica and Radalj, \v{Z}eljko and Vrtar, Mladen and Cerovac, Zdravko and Kova\v{c}evi\'{c}, Nenad and Gladi\'{c}, Jadranko}, year = {2001}, pages = {205-205}, keywords = {External Dosimetry, Digital dosemeters, Quality Assurance, Radiation Protection}, title = {Digital Dosemeter and \#34;ALARA OD 2 - ORT and \#34; Monitoring Assembly}, keyword = {External Dosimetry, Digital dosemeters, Quality Assurance, Radiation Protection}, publisher = {MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,}, publisherplace = {Dubrovnik, Hrvatska} }
@article{article, author = {Prli\'{c}, Ivica and Radalj, \v{Z}eljko and Vrtar, Mladen and Cerovac, Zdravko and Kova\v{c}evi\'{c}, Nenad and Gladi\'{c}, Jadranko}, year = {2001}, pages = {205-205}, keywords = {External Dosimetry, Digital dosemeters, Quality Assurance, Radiation Protection}, title = {Digital Dosemeter and \#34;ALARA OD 2 - ORT and \#34; Monitoring Assembly}, keyword = {External Dosimetry, Digital dosemeters, Quality Assurance, Radiation Protection}, publisher = {MZTHR, MZHR, MEHR, DZSMHR, CRPI, RBI, IMI,}, publisherplace = {Dubrovnik, Hrvatska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font