Pregled bibliografske jedinice broj: 700406
Benchmark analysis of EBR–II shutdown heat removal test SHRT–17
Benchmark analysis of EBR–II shutdown heat removal test SHRT–17 // Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids / Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko (ur.).
Zagreb: Hrvatsko nuklearno društvo, 2014. str. 125-1 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 700406 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Benchmark analysis of EBR–II shutdown heat removal test SHRT–17
Autori
Ivan Horvatovic ; Chirayu Batra ; Marco Cherubini ; Alessandro Petruzzi ; Francesco D’Auria ; Bajs, Tomislav
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids
/ Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko - Zagreb : Hrvatsko nuklearno društvo, 2014, 125-1
ISBN
978-953-55224-6-1
Skup
10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids
Mjesto i datum
Zadar, Hrvatska, 01.06.2014. - 04.06.2014
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
EBR-II; Sodium-cooled fast reactors; SHRT-17; RELAP-3D; protected loss-of-flow
Sažetak
Coordinated Research Project (CRP) on EBR-II Shutdown Heat Removal Tests (SHRT) was established by International Atomic Energy Agency (IAEA). The aim of the project is to support and to improve validation of simulation tools and projects for Sodium-cooled Fast Reactors (SFR). The Experimental Breeder Reactor II (EBR-II) plant was a uranium metalalloy- fuelled liquid-metal-cooled fast reactor designed and operated by Argonne National Laboratory (ANL) for the U.S. Department of Energy at the Argonne-West site. In the frame of this project, benchmark analysis of one of the EBR-II shutdown heat removal tests, protected loss-of-flow transient (SHRT-17), has been performed at the Gruppo di Ricerca Nucleare San Piero a Grado (GRNSPG) in Pisa, Italy. The aim of this paper is to present modelling of EBR-II reactor design using RELAP-3D, and to present results of the transient analysis of SHRT- 17. Complete nodalization of the reactor was made from the beginning. Model is divided in primary side that contains core, pumps, reactor pool and, for this kind of reactor specific, Z pipe, and intermediate side that contains Intermediate Heat Exchanger (IHX). After achievement of acceptable steady-state results, transient analysis was performed. Starting from full power and flow, both the primary loop and intermediate loop coolant pumps were simultaneously tripped and the reactor was scrammed to simulate a protected loss-of-flow accident. In addition, the primary system auxiliary coolant pump that normally had an emergency battery power supply was turned off. Despite early rise of the temperature in the reactor, the natural circulation characteristics managed to keep it at acceptable leveles and cooled the reactor down safely at decay heat power levels. Thermal-hydraulics characteristics and plant behaviour was focused on prediction of natural convection cooling by evaluating the reactor core flow and temperatures and their comparison with experimental data that were provided by ANL. The plan is to improve the model in future with replacing current models of core and pool with 3D models, and, eventually, coupling with neutronic codes for more accurate results.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika
POVEZANOST RADA
Projekti:
036-0361590-1589 - Nuklearne elektrane za održivu proizvodnju električne energije (Feretić, Danilo, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb
Profili:
Tomislav Bajs
(autor)