Possibilities of Ultrasound Catheters
Possibilities of Ultrasound Catheters // International journal of cardiac imaging, 6 (1991), 3/4; 277-284 doi:10.1007/BF01797859 (podatak o recenziji nije dostupan, članak, znanstveni)
CROSBI ID: 687681 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Possibilities of Ultrasound Catheters
Autori
Breyer, Branko ; Ferek-Petrić, Božidar
Izvornik
International journal of cardiac imaging (0167-9899) 6
(1991), 3/4;
277-284
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
ultrasonically marked catheter ; axial blood flow ; wave guide catheter
Sažetak
Ultrasound catheters offer the possibility of various non-imaging applications. Some of these applications, now in different stages of development, have been studied and will be described here in some detail. Ultrasonically marked catheters have different applications. The catheter has a miniature marker transducer mounted at the tip or some other place of interest. Initially, this device was used to localize the pacing lead tip in the heart. Connected to a transponder of a passive type this device can generate a visible localization mark on the echograph screen. The basically same system can be used for early detection of cracking of the pacing lead insulation. In this case the marker transducer works as a high-frequency signal generator and detects characteristic capacitance changes better than other methods. The electronic circuit for measurement is built into the pacemaker. Other non-imaging applications have also been studied. The marker transducer can be used for echo ranging of the distance between a His bundle fulguration electrode and the structure to be destroyed. Such an automatic 'proximity fuse' can help to avoid the firing of energy at too great a distance from the His bundle. Technology of implantable defibrillators yields the possibility for a double transducer arrangement, one transducer mounted at the patch and the other being the marker transducer. Using on-line distance measurement this arrangement enables early detection of abnormal movement of the ventricle wall, thus detecting deterioration of the muscle function before it is electrically evident. The measurement was simulated in-vitro. Measurement of axial blood flow using transit time methods, instead of Doppler, was also experimentally studied.
Izvorni jezik
Engleski
Znanstvena područja
Elektrotehnika, Kliničke medicinske znanosti
Napomena
Nagrada za znanstveni rad Nikola Tesla dodjeljena je
1985. godine znanstvenicima Branku Breyeru, Ivi Čikešu
i Božidaru Ferek-Petriću za otkriće ultrazvučno
označenih katetera.
POVEZANOST RADA
Ustanove:
Klinički bolnički centar Zagreb
Citiraj ovu publikaciju:
Časopis indeksira:
- Scopus
- MEDLINE
Uključenost u ostale bibliografske baze podataka::
- MEDLINE