Acute afterload increase causes mechanical dispersion — potential mechanism for pressure induced arrhythmias?
Acute afterload increase causes mechanical dispersion — potential mechanism for pressure induced arrhythmias? // Cardiologia Croatica
Dubrovnik, Hrvatska, 2013. str. 305-306 (poster, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 671272 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Acute afterload increase causes mechanical dispersion — potential mechanism for pressure induced arrhythmias?
Autori
Jakuš, Nina ; Sutherland, George ; Čikeš, Maja ; Haemers, Peter ; Voigt, Jens Uwe ; Rademakers, Frank ; Willems, Rik ; D'hooge, Jan ; Claus, Piet.
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Cardiologia Croatica
/ - , 2013, 305-306
Skup
3rd Dubrovnik Cardiology Highlights
Mjesto i datum
Dubrovnik, Hrvatska, 26.09.2013. - 29.09.2013
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Mechanical dispersion; cardiovascular experimental model; pressure increase; speckle tracking imaging.
Sažetak
Aim: We have recently shown that an acute afterload increase of the left ventricle induces premature ventricular beats (PVB). We explored mechanical dispersion, which has recently been linked to a greater incidence of arrhythmias in post infarction ICD patients, as a potential underlying mechanism. Methods: 7 closed chest, closed pericardium pigs were instrumented with an aortic balloon in the mid-thoracic descending aorta. Parasternal long- axis B-mode images were acquired before and during the balloon inflation (N=22), causing a 30% increase in systolic blood pressure and an acute LV dilatation over 5-10 beats. Before and during inflation, segmental septal deformation was analyzed using speckle tracking and timing and the amount of peak strain were measured. Mechanical dispersion was calculated as the standard deviation (SD) of the time to peak strain in the three segments. 12 lead ECG was acquired in all animals. Results: PVBs occurred in 33% of the pressure challenges. The afterload increase caused a visible dispersion in the timing of the strain curves of the three segments (Figure 1a). Despite no change in QT interval, mean time of peak strain increased from 291 ± 81ms, in preinflation to 352 ± 56ms during inflation in the three segments, resulting in post-systolic shortening. The SD increased significantly from preinflation to inflation (p=0.02) (Figure 1b). While strain at aortic valve closure clearly went down with afterload (-14.74±6 to -11.04±4.02, p=0.0001), peak shortening remained similar (-15.79±6.09 to -15.12±4.56, p=0.479). Conclusion: Acute afterload increase of the LV significantly increased the difference in time to peak strain between the three septal segments, resulting in increased mechanical dispersion, which may play a role in pressure-induced arrhythmias.