Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 654096

The possibility of changing algorithm for confirmatory immunohematological testing by indirect antiglobulin test in Croatian blood donors


Kruhonja Galić, Zrinka; Jagnjić, Sandra; Hundrić Hašpl, Željka; Juraković Lončar, Nina; Tomičić, Maja; Hećimović, Ana; Balija, Melita; Jukić, Irena
The possibility of changing algorithm for confirmatory immunohematological testing by indirect antiglobulin test in Croatian blood donors // Abstracts of the 23rd Regional Congress of the International Society of Blood Transfusion : u: Vox Sanguinis 105 (2013)(S1) 65-299 ; P-411 / Devine, D. (ur.).
Oxford: Blackwell Publishing, 2013. str. 206-206 (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 654096 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The possibility of changing algorithm for confirmatory immunohematological testing by indirect antiglobulin test in Croatian blood donors

Autori
Kruhonja Galić, Zrinka ; Jagnjić, Sandra ; Hundrić Hašpl, Željka ; Juraković Lončar, Nina ; Tomičić, Maja ; Hećimović, Ana ; Balija, Melita ; Jukić, Irena

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Abstracts of the 23rd Regional Congress of the International Society of Blood Transfusion : u: Vox Sanguinis 105 (2013)(S1) 65-299 ; P-411 / Devine, D. - Oxford : Blackwell Publishing, 2013, 206-206

Skup
Regional Congress of the International Society of Blood Transfusion (23 ; 2013)

Mjesto i datum
Amsterdam, Nizozemska, 02.06.2013. - 05.06.2013

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
algorithm IAT blood donors

Sažetak
Blood units for transfusion therapy must not have clinically significant red blood cell (RBC) antibodies (Abs). According to the literature data, clinically significant in vivo destruction of patient’s RBCs will occur only after transfusion of at least one unit plasma with clinically significant RBC Abs with titer more than 128. Because of that, weak positive reactions (score < 5) in sensitive micromethods do not refer to the presence of RBC Abs with the potential of causing RBC destruction in blood recipient. Aim was to point out specificity and serological activity of RBC Abs in blood donors with RBC Abs, and to estimate the posibility of changing algorithm for confirmatory testing performing in glass beads technology of blood donors in CITM. We examine 294 blood donors withRBC Abs from the CITM database from 2001 to 2010. RBC Abs screening was performed by Solidscreen II (Bio-Rad Laboratories, Dreieich, Germany). Confirmatory testing was done in microcards by gel technology (ID-Card Bio-Rad Laboratories, DiaMed GmbH, Cressier FR, Switzerland). After negative results in gel technology, according to CITM algorithm, confirmation was done in glass beads technology (Bio Vue System, Ortho Clinical Diagnostics, Raritain, USA) following manufacturer’s package inserts. From 294 blood donors, 24 had clinically insignificant RBC Abs, 117 had RBC Abs with possible clinical significance and 153 had clinically significant RBC Abs. Among them there were 94 (32%) blood donors with RBC Abs of scores < 5 in glass beads technology and negative in gel technology. Those blood donors which were in immunohematological testing of RBC Abs reactive in glass beads technology were in third of cases non reactive in gel technology. Respacting the significance of each donated blood unit, we introduced gel technology as a standard for confirmatory immunohematological testing of blood donors in CITM.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti

Napomena
DOI: 10.1111/vox.12048



POVEZANOST RADA


Ustanove:
Hrvatski zavod za transfuzijsku medicinu

Citiraj ovu publikaciju:

Kruhonja Galić, Zrinka; Jagnjić, Sandra; Hundrić Hašpl, Željka; Juraković Lončar, Nina; Tomičić, Maja; Hećimović, Ana; Balija, Melita; Jukić, Irena
The possibility of changing algorithm for confirmatory immunohematological testing by indirect antiglobulin test in Croatian blood donors // Abstracts of the 23rd Regional Congress of the International Society of Blood Transfusion : u: Vox Sanguinis 105 (2013)(S1) 65-299 ; P-411 / Devine, D. (ur.).
Oxford: Blackwell Publishing, 2013. str. 206-206 (poster, međunarodna recenzija, sažetak, znanstveni)
Kruhonja Galić, Z., Jagnjić, S., Hundrić Hašpl, Ž., Juraković Lončar, N., Tomičić, M., Hećimović, A., Balija, M. & Jukić, I. (2013) The possibility of changing algorithm for confirmatory immunohematological testing by indirect antiglobulin test in Croatian blood donors. U: Devine, D. (ur.)Abstracts of the 23rd Regional Congress of the International Society of Blood Transfusion : u: Vox Sanguinis 105 (2013)(S1) 65-299 ; P-411.
@article{article, author = {Kruhonja Gali\'{c}, Zrinka and Jagnji\'{c}, Sandra and Hundri\'{c} Ha\v{s}pl, \v{Z}eljka and Jurakovi\'{c} Lon\v{c}ar, Nina and Tomi\v{c}i\'{c}, Maja and He\'{c}imovi\'{c}, Ana and Balija, Melita and Juki\'{c}, Irena}, editor = {Devine, D.}, year = {2013}, pages = {206-206}, keywords = {algorithm IAT blood donors}, title = {The possibility of changing algorithm for confirmatory immunohematological testing by indirect antiglobulin test in Croatian blood donors}, keyword = {algorithm IAT blood donors}, publisher = {Blackwell Publishing}, publisherplace = {Amsterdam, Nizozemska} }
@article{article, author = {Kruhonja Gali\'{c}, Zrinka and Jagnji\'{c}, Sandra and Hundri\'{c} Ha\v{s}pl, \v{Z}eljka and Jurakovi\'{c} Lon\v{c}ar, Nina and Tomi\v{c}i\'{c}, Maja and He\'{c}imovi\'{c}, Ana and Balija, Melita and Juki\'{c}, Irena}, editor = {Devine, D.}, year = {2013}, pages = {206-206}, keywords = {algorithm IAT blood donors}, title = {The possibility of changing algorithm for confirmatory immunohematological testing by indirect antiglobulin test in Croatian blood donors}, keyword = {algorithm IAT blood donors}, publisher = {Blackwell Publishing}, publisherplace = {Amsterdam, Nizozemska} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font