Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 652647

The seasonal dependence of PM10 Equivalence testing


Bešlić, Ivan; Šega, Krešimir; Davila, Silvije
The seasonal dependence of PM10 Equivalence testing // Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"
Cape Town: National Association for Clean Air, 2013. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)


CROSBI ID: 652647 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The seasonal dependence of PM10 Equivalence testing

Autori
Bešlić, Ivan ; Šega, Krešimir ; Davila, Silvije

Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni

Izvornik
Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability" / - Cape Town : National Association for Clean Air, 2013

ISBN
978-0-620-58320-6

Skup
16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"

Mjesto i datum
Cape Town, Južnoafrička Republika, 29.09.2013. - 04.10.2013

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
PM10; orthogonal regression; correction function; expanded measuring uncertainty

Sažetak
The equivalence testing of automatic analysers and non-referent samplers for PM10 particle fractions with referent samplers is required according to European Directive 2008/50/EC. The aim of this article was to assess the annual and seasonal correction functions for the ESM Andersen FH-61 IR automatic analyser and for the HVS Digitel DH-80 nonreferent sampler. For the purposes of equivalence testing, the LVS Sven Leckel SEQ referent sampler was used. Furthermore, the aim of this investigation was to determine the influence of equivalence testing on statistical parameters for air quality assessment. The non-referent devices did not satisfy the measuring uncertainty requirements (U < 25 %) for both yearly and seasonal data sets. The corrected results satisfied the measuring uncertainty requirements, except for the autumn data sets and the yearly data set obtained by the automatic analyser. The statistical parameters for air quality assessment obtained by non-referent devices were significantly lower than the parameters obtained by the referent sampler. The correction functions of non-referent devices significantly differed among each other. This analysis points out the necessity of seasonal corrections of PM10 concentrations obtained by non-referent devices.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekti:
022-0222882-2271 - Vremensko-prostorna razdioba i porijeklo lebdećih čestica u urbanim sredinama (Šega, Krešimir, MZOS ) ( CroRIS)

Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb

Profili:

Avatar Url Ivan Bešlić (autor)

Avatar Url Silvije Davila (autor)

Avatar Url Krešimir Šega (autor)


Citiraj ovu publikaciju:

Bešlić, Ivan; Šega, Krešimir; Davila, Silvije
The seasonal dependence of PM10 Equivalence testing // Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"
Cape Town: National Association for Clean Air, 2013. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
Bešlić, I., Šega, K. & Davila, S. (2013) The seasonal dependence of PM10 Equivalence testing. U: Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability".
@article{article, author = {Be\v{s}li\'{c}, Ivan and \v{S}ega, Kre\v{s}imir and Davila, Silvije}, year = {2013}, pages = {Full\_paper\_0045}, keywords = {PM10, orthogonal regression, correction function, expanded measuring uncertainty}, isbn = {978-0-620-58320-6}, title = {The seasonal dependence of PM10 Equivalence testing}, keyword = {PM10, orthogonal regression, correction function, expanded measuring uncertainty}, publisher = {National Association for Clean Air}, publisherplace = {Cape Town, Ju\v{z}noafri\v{c}ka Republika} }
@article{article, author = {Be\v{s}li\'{c}, Ivan and \v{S}ega, Kre\v{s}imir and Davila, Silvije}, year = {2013}, pages = {Full\_paper\_0045}, keywords = {PM10, orthogonal regression, correction function, expanded measuring uncertainty}, isbn = {978-0-620-58320-6}, title = {The seasonal dependence of PM10 Equivalence testing}, keyword = {PM10, orthogonal regression, correction function, expanded measuring uncertainty}, publisher = {National Association for Clean Air}, publisherplace = {Cape Town, Ju\v{z}noafri\v{c}ka Republika} }




Contrast
Increase Font
Decrease Font
Dyslexic Font