Pregled bibliografske jedinice broj: 652647
The seasonal dependence of PM10 Equivalence testing
The seasonal dependence of PM10 Equivalence testing // Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"
Cape Town: National Association for Clean Air, 2013. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 652647 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
The seasonal dependence of PM10 Equivalence testing
Autori
Bešlić, Ivan ; Šega, Krešimir ; Davila, Silvije
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"
/ - Cape Town : National Association for Clean Air, 2013
ISBN
978-0-620-58320-6
Skup
16th IUAPPA World Clean Air Congress - "Many Nations - One Atmosphere: Plotting the Path to Sustainability"
Mjesto i datum
Cape Town, Južnoafrička Republika, 29.09.2013. - 04.10.2013
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
PM10; orthogonal regression; correction function; expanded measuring uncertainty
Sažetak
The equivalence testing of automatic analysers and non-referent samplers for PM10 particle fractions with referent samplers is required according to European Directive 2008/50/EC. The aim of this article was to assess the annual and seasonal correction functions for the ESM Andersen FH-61 IR automatic analyser and for the HVS Digitel DH-80 nonreferent sampler. For the purposes of equivalence testing, the LVS Sven Leckel SEQ referent sampler was used. Furthermore, the aim of this investigation was to determine the influence of equivalence testing on statistical parameters for air quality assessment. The non-referent devices did not satisfy the measuring uncertainty requirements (U < 25 %) for both yearly and seasonal data sets. The corrected results satisfied the measuring uncertainty requirements, except for the autumn data sets and the yearly data set obtained by the automatic analyser. The statistical parameters for air quality assessment obtained by non-referent devices were significantly lower than the parameters obtained by the referent sampler. The correction functions of non-referent devices significantly differed among each other. This analysis points out the necessity of seasonal corrections of PM10 concentrations obtained by non-referent devices.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Javno zdravstvo i zdravstvena zaštita
POVEZANOST RADA
Projekti:
022-0222882-2271 - Vremensko-prostorna razdioba i porijeklo lebdećih čestica u urbanim sredinama (Šega, Krešimir, MZOS ) ( CroRIS)
Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb