Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 650695

Comparison of indoor and outdoor concentrations of formaldehyde in high schools in Osijek, Croatia


Brdarić, Dario; Valek, Marina; Rudan, Stjepan; Egorov, Andrey
Comparison of indoor and outdoor concentrations of formaldehyde in high schools in Osijek, Croatia // 5th Congress and 40th October Meeting
Ohrid, Sjeverna Makedonija, 2012. (predavanje, međunarodna recenzija, sažetak, ostalo)


CROSBI ID: 650695 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparison of indoor and outdoor concentrations of formaldehyde in high schools in Osijek, Croatia

Autori
Brdarić, Dario ; Valek, Marina ; Rudan, Stjepan ; Egorov, Andrey

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, ostalo

Skup
5th Congress and 40th October Meeting

Mjesto i datum
Ohrid, Sjeverna Makedonija, 03.10.2012. - 07.10.2012

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
pilot survey; indoor air quality; formaldehyde; high schools

Sažetak
Aim: School age children spend substantial part of their time indoors in schools. Formaldehyde is reactive gas emitted by a variety of off- gassing sources, such as particle boards, varnishes and paints, and combustion sources including tobacco smoking. It is classified as a human carcinogen and can cause irritation of mucous membranes and aggravation of asthma. Measurements of formaldehyde in classrooms were part of a pilot WHO-coordinated survey to assess exposure to environmental factors in schools. Materials and methods: Eight samples were collected using passive diffusion samplers (Radiello, code 165) in two high schools (6 classrooms and 2 outdoor sites) in Osijek, Croatia during a four-day period in April 2012. Samples were extracted with acetonitrile and analyzed using reverse phase HPLC with UV detection. Results: Concentrations of formaldehyde in classrooms ranged from 5.9 to 11.1 µg/m3 (mean 8.4 µg/m3). Concentrations at outdoor sites sample were 1.3 and 2.3 µg/m3 (mean 1.8 µg/m3). Mean formaldehyde level in classrooms was 4.7 times higher than at outdoor sites. Conclusions: This pilot survey successfully demonstrated the application of a standard WHO methodology. The concentrations of formaldehyde measured in two schools are within the range previously reported in neighboring countries. These exposure levels do not pose immediate risk of acute health effects. A larger survey is necessary in order to characterize formaldehyde concentrations in Croatian schools. Acknowledgement: This survey used the methodology developed by the WHO ECEH / EC Joint Research Centre (JRC) joint working group on indoor air quality surveillance in schools.

Izvorni jezik
Engleski

Znanstvena područja
Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Ustanove:
Nastavni zavod za javno zdravstvo "Dr. Andrija Štampar"

Profili:

Avatar Url Dario Brdarić (autor)

Avatar Url Stjepan Rudan (autor)


Citiraj ovu publikaciju:

Brdarić, Dario; Valek, Marina; Rudan, Stjepan; Egorov, Andrey
Comparison of indoor and outdoor concentrations of formaldehyde in high schools in Osijek, Croatia // 5th Congress and 40th October Meeting
Ohrid, Sjeverna Makedonija, 2012. (predavanje, međunarodna recenzija, sažetak, ostalo)
Brdarić, D., Valek, M., Rudan, S. & Egorov, A. (2012) Comparison of indoor and outdoor concentrations of formaldehyde in high schools in Osijek, Croatia. U: 5th Congress and 40th October Meeting.
@article{article, author = {Brdari\'{c}, Dario and Valek, Marina and Rudan, Stjepan and Egorov, Andrey}, year = {2012}, keywords = {pilot survey, indoor air quality, formaldehyde, high schools}, title = {Comparison of indoor and outdoor concentrations of formaldehyde in high schools in Osijek, Croatia}, keyword = {pilot survey, indoor air quality, formaldehyde, high schools}, publisherplace = {Ohrid, Sjeverna Makedonija} }
@article{article, author = {Brdari\'{c}, Dario and Valek, Marina and Rudan, Stjepan and Egorov, Andrey}, year = {2012}, keywords = {pilot survey, indoor air quality, formaldehyde, high schools}, title = {Comparison of indoor and outdoor concentrations of formaldehyde in high schools in Osijek, Croatia}, keyword = {pilot survey, indoor air quality, formaldehyde, high schools}, publisherplace = {Ohrid, Sjeverna Makedonija} }