Pregled bibliografske jedinice broj: 637645
Impact of fluoride agents on mechanical properties of orthodontic wires
Impact of fluoride agents on mechanical properties of orthodontic wires // Biodental Engineering II / Natal Jorge, RM, Reis Campos, JC, Tavares, JMRS, Vaz, MAP, Santos, SM. (ur.).
London : Delhi: CRC Press ; A.A. Balkema Publishers, 2014. str. 39-43 (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 637645 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Impact of fluoride agents on mechanical properties of orthodontic wires
Autori
Katić, Višnja ; Špalj, Stjepan ; Leder Horina, Jasna ; Vikić-Topić, Dražen.
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Biodental Engineering II
/ Natal Jorge, RM, Reis Campos, JC, Tavares, JMRS, Vaz, MAP, Santos, SM. - London : Delhi : CRC Press ; A.A. Balkema Publishers, 2014, 39-43
ISBN
978-1-138-00131-2
Skup
Biodental Engineering II
Mjesto i datum
Porto, Portugal, 07.12.2012. - 08.12.2012
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
NiTi wire; wire coating; fluoride agents; mechanical properties
Sažetak
Effects of fluoride prophylactic agents on mechanical properties of regular and nitrified nickel-titanium (Ni-Ti) Bioforce Sentalloy wires were investigated. Specimens (25 × 0.508 × 0.508 mm) were immersed in Elmex gelée, MI Paste Plus and dH2O (control) for 1 hour at 37°C. After immersion, the loading and unloading elas-tic modulus (E) and yield strength (YS) of ten samples from each group were measured with a 3-point bend- ing test in a thermal chamber at 37°C. ANOVA and Games-Howell post-hoc test were used in statistical anal-ysis. The unloading YS of Ni-Ti for Elmex gelée is significantly higher in respect to dH2O (p=0.007). In dH2O, Ni-Ti showed significantly lower results in unloading YS, when compared to nitrified Ni-Ti (p=0.029). Dark discolorations are visible in all tested groups. Elmex gelée affects significantly unloading mechanical properties of regular Ni-Ti wire. MI Paste Plus has no significant effect on mechanical properties of tested wires.
Izvorni jezik
Engleski
Znanstvena područja
Strojarstvo, Dentalna medicina
POVEZANOST RADA
Projekti:
058-0581846-0422 - Pripremanje sirovina i određivanje teksturalnih svojstava prehrambenih proizvoda (Ježek, Damir, MZOS ) ( CroRIS)
120-1962766-3109 - VIRTUALNA TRODIMENZIJSKA PRIMJENJENA ANTROPOLOGIJA (Jurčević-Lulić, Tanja, MZOS ) ( CroRIS)
Ustanove:
Medicinski fakultet, Rijeka,
Fakultet strojarstva i brodogradnje, Zagreb
Profili:
Višnja Katić
(autor)
Jasna Leder Horina
(autor)
Stjepan Špalj
(autor)
Dražen Vikić-Topić
(autor)