Improving Clinical Translation of Cardiovascular Circulatory Models through an Intuitive Graphical User Interface to CircAdapt, Presenting Simulation Results as Clinical Images and Signals
Improving Clinical Translation of Cardiovascular Circulatory Models through an Intuitive Graphical User Interface to CircAdapt, Presenting Simulation Results as Clinical Images and Signals // STACOM
Nica, Francuska, 2012. str. 345-354 (poster, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 633653 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Improving Clinical Translation of Cardiovascular Circulatory Models through an Intuitive Graphical User Interface to CircAdapt, Presenting Simulation Results as Clinical Images and Signals
Autori
Palau-Caballero, Georgina ; Tobon-Gomez, Catalina ; Balicevic, Vedrana ; Butakoff, Constantine ; Loncaric, Sven ; Sitges, Marta ; Bijnens, Bart H.
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
STACOM
/ - , 2012, 345-354
Skup
15. MICCAI 2012: Nice, France - STACOM
Mjesto i datum
Nica, Francuska, 01.10.2012. - 05.10.2012
Vrsta sudjelovanja
Poster
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
Cardiovascular Circulatory Models; CircAdapt; GUI; Pulsed Wave Doppler
Sažetak
Despite the great potential of computational models, their clinical use is limited due to lack of clinical translation. It is, therefore, desirable to present and visualise simulation results as regular imaging data commonly used in clinical practice. The purpose of this paper is to present an implementation of a graphical user interface (GUI) for the lumped model CircAdapt. The GUI displays simulation results as: 1) an animated schematic short-axis view of ventricular geometry, 2) a Wiggers diagram relating pressure and volume curves with clear indication of the timing events within the cardiac cycle, 3) a simulated Pulsed Wave Doppler echocardiographic image of mitral/aortic and tricuspid/pulmonary flow, and, 4) a B-Mode echocardiographic image of short- axis ventricular geometry. We have modeled different physiological and pathological conditions to illustrate the applicability of the GUI: normal state, aortic stenosis and acute response to exercise with high pulmonary vascular resistance.
Izvorni jezik
Engleski
Znanstvena područja
Računarstvo, Kliničke medicinske znanosti
POVEZANOST RADA
Projekti:
036-0362214-1989 - Inteligentne metode obrade i analize slika (Lončarić, Sven, MZO ) ( CroRIS)
Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb