Evaluation of the Nihon Kohden MEK-8118K automated blood counter


Petani, Sandra; Topić, Elizabeta; Turčić, Graciela; Lora, Dukić
Evaluation of the Nihon Kohden MEK-8118K automated blood counter // Clinical laboratory (Heidelberg. 1996), 42 (1996), 7/8; 579-587 (podatak o recenziji nije dostupan, članak, stručni)


CROSBI ID: 6214 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Evaluation of the Nihon Kohden MEK-8118K automated blood counter

Autori
Petani, Sandra ; Topić, Elizabeta ; Turčić, Graciela ; Lora, Dukić

Izvornik
Clinical laboratory (Heidelberg. 1996) (1433-6510) 42 (1996), 7/8; 579-587

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, stručni

Ključne riječi
MEK-8118K hematology analyzer ; differential leukocyte count ; three-part differential count ; blood counter evaluation

Sažetak
The Nihon Kohden MEK-8118K automated blood counter was evaluated in regard with within-run and between-run precision, carryover and accuracy. Sensitivity and specificity of the instrument were determined by comparing the manual and instrument differentiation. Within-run and between-run precision showed satisfactory results for all parameters determined. Accuracy of the measurement tested by comparison of the results simultaneously obtained on the MINOS STE (Cobas, Roche) and MEK-8118K (Nihon Kohden) analyzers showed satisfactory correlation coefficients for nearly all parameters (WBC r=0.99, RBC r=0.91, HGB r=0.99, HCT r=0.97, MCV r=0.94, MCH r=0.92, PLT r=0.98), except for MCHC (r=0.15). The three-part differential blood count produced by the MEK-8118K was compared to the reference manual method, satisfactory correlation were obtained for granulocytes (r=0.94) and lymphocytes (r=0.92), whereas for mononuclears it was lower (r=0.59) indicating sensitivity of 91% and specificity of 92% of the MEK-8118K. Results of the evaluation showed the MEK-8118K hematology analyser to be a precise, accurate and reliable instrument in blood count determination and in signalising changes in differential blood count. In such cases, however, the blood sample should also be microscopically examined to verify the possible changes in the distribution and/or morphology of particular types of leukocytes.

Izvorni jezik
Engleski

Znanstvena područja
Temeljne medicinske znanosti



POVEZANOST RADA


Projekti:
134003

Ustanove:
KBC "Sestre Milosrdnice"

Profili:

Avatar Url Elizabeta Topić (autor)

Avatar Url Lora Dukić (autor)

Citiraj ovu publikaciju:

Petani, Sandra; Topić, Elizabeta; Turčić, Graciela; Lora, Dukić
Evaluation of the Nihon Kohden MEK-8118K automated blood counter // Clinical laboratory (Heidelberg. 1996), 42 (1996), 7/8; 579-587 (podatak o recenziji nije dostupan, članak, stručni)
Petani, S., Topić, E., Turčić, G. & Lora, D. (1996) Evaluation of the Nihon Kohden MEK-8118K automated blood counter. Clinical laboratory (Heidelberg. 1996), 42 (7/8), 579-587.
@article{article, author = {Petani, Sandra and Topi\'{c}, Elizabeta and Tur\v{c}i\'{c}, Graciela and Lora, Duki\'{c}}, year = {1996}, pages = {579-587}, keywords = {MEK-8118K hematology analyzer, differential leukocyte count, three-part differential count, blood counter evaluation}, journal = {Clinical laboratory (Heidelberg. 1996)}, volume = {42}, number = {7/8}, issn = {1433-6510}, title = {Evaluation of the Nihon Kohden MEK-8118K automated blood counter}, keyword = {MEK-8118K hematology analyzer, differential leukocyte count, three-part differential count, blood counter evaluation} }
@article{article, author = {Petani, Sandra and Topi\'{c}, Elizabeta and Tur\v{c}i\'{c}, Graciela and Lora, Duki\'{c}}, year = {1996}, pages = {579-587}, keywords = {MEK-8118K hematology analyzer, differential leukocyte count, three-part differential count, blood counter evaluation}, journal = {Clinical laboratory (Heidelberg. 1996)}, volume = {42}, number = {7/8}, issn = {1433-6510}, title = {Evaluation of the Nihon Kohden MEK-8118K automated blood counter}, keyword = {MEK-8118K hematology analyzer, differential leukocyte count, three-part differential count, blood counter evaluation} }

Uključenost u ostale bibliografske baze podataka::


  • CA Search (Chemical Abstracts)
  • EMBASE (Excerpta Medica)
  • BIOBASE/Current Awareness in Biological Sciences





Contrast
Increase Font
Decrease Font
Dyslexic Font