Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 615500

Internal Fixation Supracondylar Fractures of Distal Humerus: A Finite Element Analysis


Sabalić, Srećko; Muljačić, Ante; Kodvanj, Janoš; Daraboš, Nikica
Internal Fixation Supracondylar Fractures of Distal Humerus: A Finite Element Analysis // Proceedings of Combined 33rd SICOT & 17th PAOA Orthopaedic World Conference
Dubai, 2012. str. 155-155 (predavanje, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 615500 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Internal Fixation Supracondylar Fractures of Distal Humerus: A Finite Element Analysis

Autori
Sabalić, Srećko ; Muljačić, Ante ; Kodvanj, Janoš ; Daraboš, Nikica

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Proceedings of Combined 33rd SICOT & 17th PAOA Orthopaedic World Conference / - Dubai, 2012, 155-155

Skup
Combined 33rd SICOT & 17th PAOA Orthopaedic World Conference

Mjesto i datum
Dubai, Ujedinjeni Arapski Emirati, 28.11.2012. - 30.11.2012

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
biomechanics; distal humerus fracture; reconstruction plate; finite element method

Sažetak
Fractures of the distal humerus are usually treated with two reconstruction plates in a parallel or perpendicular position. There are no published biomechanical studies on supracondylar level of the distal humerus. A finite element analysis of two different methods of internal fixation, with two reconstructive plates in parallel and perpendicular, of distal humerus fractures according to the fixation techniques was performed in our biomechanical study. The gap, located 2.5 cm above the fosse olecrani, length 1 cm, mimicked the unstable fracture in supracondylar region. Six screws were set on each plate, three on each side of the gap. We performed static bending load of 100 N on the corresponding segment of the distal humerus in a flexion position of 75 degrees, the axial load in a flexion position of 5 degrees and lateral loads on the radial condyle. We analyzed the shifts in the gap and stress on the implant during load. Shift of the gap, the bending load and lateral load are significantly larger than the axial load, and thus have a greater significance in the overall strength analysis of the model. Displacements in the axial load are about 75% higher in perpendicular compared with parallel positioning plates. Displacements in bending loads are about 35% higher in perpendicular position, while no significant differences in increments of lateral load on the radial condyle. The perpendicular position of plates in fractures of the supracondylar distal humerus in the analysis finite elements method is mechanically more stable than the perpendicular position.

Izvorni jezik
Engleski

Znanstvena područja
Strojarstvo, Temeljne medicinske znanosti, Kliničke medicinske znanosti



POVEZANOST RADA


Projekti:
120-1201910-1907 - Eksperimentalna simulacija oštećenja mehaničkih i biomehaničkih sustava (Kodvanj, Janoš, MZOS ) ( CroRIS)

Ustanove:
Fakultet strojarstva i brodogradnje, Zagreb,
KBC "Sestre Milosrdnice"


Citiraj ovu publikaciju:

Sabalić, Srećko; Muljačić, Ante; Kodvanj, Janoš; Daraboš, Nikica
Internal Fixation Supracondylar Fractures of Distal Humerus: A Finite Element Analysis // Proceedings of Combined 33rd SICOT & 17th PAOA Orthopaedic World Conference
Dubai, 2012. str. 155-155 (predavanje, međunarodna recenzija, sažetak, znanstveni)
Sabalić, S., Muljačić, A., Kodvanj, J. & Daraboš, N. (2012) Internal Fixation Supracondylar Fractures of Distal Humerus: A Finite Element Analysis. U: Proceedings of Combined 33rd SICOT & 17th PAOA Orthopaedic World Conference.
@article{article, author = {Sabali\'{c}, Sre\'{c}ko and Mulja\v{c}i\'{c}, Ante and Kodvanj, Jano\v{s} and Darabo\v{s}, Nikica}, year = {2012}, pages = {155-155}, keywords = {biomechanics, distal humerus fracture, reconstruction plate, finite element method}, title = {Internal Fixation Supracondylar Fractures of Distal Humerus: A Finite Element Analysis}, keyword = {biomechanics, distal humerus fracture, reconstruction plate, finite element method}, publisherplace = {Dubai, Ujedinjeni Arapski Emirati} }
@article{article, author = {Sabali\'{c}, Sre\'{c}ko and Mulja\v{c}i\'{c}, Ante and Kodvanj, Jano\v{s} and Darabo\v{s}, Nikica}, year = {2012}, pages = {155-155}, keywords = {biomechanics, distal humerus fracture, reconstruction plate, finite element method}, title = {Internal Fixation Supracondylar Fractures of Distal Humerus: A Finite Element Analysis}, keyword = {biomechanics, distal humerus fracture, reconstruction plate, finite element method}, publisherplace = {Dubai, Ujedinjeni Arapski Emirati} }




Contrast
Increase Font
Decrease Font
Dyslexic Font