Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 612423

The need for equivalence for PM samplers


Davila, Silvije; Šega, Krešimir; Bešlić, Ivan
The need for equivalence for PM samplers // Abstracts of the 4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales / Incecik, Selahattin ; Kahya, Ceyhan (ur.).
Istanbul: Istanbul Technical University (ITU) ; Turkish National Committee for Air Pollution and Control (TUNCAP), 2012. (predavanje, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 612423 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
The need for equivalence for PM samplers

Autori
Davila, Silvije ; Šega, Krešimir ; Bešlić, Ivan

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
Abstracts of the 4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales / Incecik, Selahattin ; Kahya, Ceyhan - Istanbul : Istanbul Technical University (ITU) ; Turkish National Committee for Air Pollution and Control (TUNCAP), 2012

Skup
4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales

Mjesto i datum
Istanbul, Turska, 10.09.2012. - 13.09.2012

Vrsta sudjelovanja
Predavanje

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
PM10; correction factors; Utility v.2.8

Sažetak
We performed equivalence testing by comparing mass concentrations of PM10 particle fraction measured by β-attenuation and by gravimetric method. Samples were collected during the period 1 January 2010 - 31 December 2011. The comparison was performed between gravimetric method described in EN12341 on a non-referent sampler (HVC Digitel HD-80) and an automatic analyzer (ESM ANDERSEN FH 61 IR). Results were analyzed using a computer spreadsheet, "Orthogonal regression and the test equivalence Utility v.2.8" developed at the RIVM (Dutch Institute for Public Health and the Environment, Dep. Centre for Environment Monitoring). Annual correction of results shows a satisfactory degree of equivalence for year 2010, but not for 2011. Seasonal correction meets the requirement of equivalence of the results for both years of measurement.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Javno zdravstvo i zdravstvena zaštita



POVEZANOST RADA


Projekti:
022-0222882-2271 - Vremensko-prostorna razdioba i porijeklo lebdećih čestica u urbanim sredinama (Šega, Krešimir, MZOS ) ( CroRIS)

Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb

Profili:

Avatar Url Ivan Bešlić (autor)

Avatar Url Krešimir Šega (autor)

Avatar Url Silvije Davila (autor)


Citiraj ovu publikaciju:

Davila, Silvije; Šega, Krešimir; Bešlić, Ivan
The need for equivalence for PM samplers // Abstracts of the 4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales / Incecik, Selahattin ; Kahya, Ceyhan (ur.).
Istanbul: Istanbul Technical University (ITU) ; Turkish National Committee for Air Pollution and Control (TUNCAP), 2012. (predavanje, međunarodna recenzija, sažetak, znanstveni)
Davila, S., Šega, K. & Bešlić, I. (2012) The need for equivalence for PM samplers. U: Incecik, S. & Kahya, C. (ur.)Abstracts of the 4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales.
@article{article, author = {Davila, Silvije and \v{S}ega, Kre\v{s}imir and Be\v{s}li\'{c}, Ivan}, year = {2012}, pages = {57}, keywords = {PM10, correction factors, Utility v.2.8}, title = {The need for equivalence for PM samplers}, keyword = {PM10, correction factors, Utility v.2.8}, publisher = {Istanbul Technical University (ITU) ; Turkish National Committee for Air Pollution and Control (TUNCAP)}, publisherplace = {Istanbul, Turska} }
@article{article, author = {Davila, Silvije and \v{S}ega, Kre\v{s}imir and Be\v{s}li\'{c}, Ivan}, year = {2012}, pages = {57}, keywords = {PM10, correction factors, Utility v.2.8}, title = {The need for equivalence for PM samplers}, keyword = {PM10, correction factors, Utility v.2.8}, publisher = {Istanbul Technical University (ITU) ; Turkish National Committee for Air Pollution and Control (TUNCAP)}, publisherplace = {Istanbul, Turska} }




Contrast
Increase Font
Decrease Font
Dyslexic Font