Pregled bibliografske jedinice broj: 593687
Comparison of equivalence tests for PM samplers
Comparison of equivalence tests for PM samplers // Proceedings of the 4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales" / Incecik, Selahattin ; Kahya, Ceyhan (ur.).
Istanbul: Istanbul Technical University (ITU) ; Turkish National Committee for Air Pollution and Control (TUNCAP), 2012. (predavanje, međunarodna recenzija, cjeloviti rad (in extenso), znanstveni)
CROSBI ID: 593687 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of equivalence tests for PM samplers
Autori
Bešlić, Ivan ; Šega, Krešimir ; Godec, Ranka ; Davila, Silvije
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), znanstveni
Izvornik
Proceedings of the 4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales"
/ Incecik, Selahattin ; Kahya, Ceyhan - Istanbul : Istanbul Technical University (ITU) ; Turkish National Committee for Air Pollution and Control (TUNCAP), 2012
Skup
4th International Symposium & IUAPPA Regional Conference "Air Quality Management at Urban, Regional and Global Scales"
Mjesto i datum
Istanbul, Turska, 10.09.2012. - 13.09.2012
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
EN 12341; equivalence test utility software; gravimetric method
Sažetak
Daily PM10, PM2.5 and PM1 samples were collected simultaneously by referent and home made samplers during 2010 on different types of quartz filters. Study compares different samplers and different quartz filters according to the procedure defined by European standard EN 12341, as well as by the equivalence test utility software developed in Dutch Institute for Public Health and Environment (RIVM). Investigation showed that results are not dependent on filter brand and type and the way of their preparation before sampling. Non-referent home made samplers passed comparability test according to EN 12341 for all investigated particle fractions as well as equivalence test performed by utility software. The main contribution of this investigation is applicability of equivalence test utility software on particle fraction samplers in spite of the fact that it was basically developed for equivalence testing of automatic samplers. In addition, calibration procedure defined in utility software is fully applicable for the correction of the results obtained by non-referent samplers.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Javno zdravstvo i zdravstvena zaštita
POVEZANOST RADA
Projekti:
022-0222882-2271 - Vremensko-prostorna razdioba i porijeklo lebdećih čestica u urbanim sredinama (Šega, Krešimir, MZOS ) ( CroRIS)
Ustanove:
Institut za medicinska istraživanja i medicinu rada, Zagreb