Effect of Electrodes Configurations on the Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz


Lučev, Željka; Krois, Igor; Cifrek, Mario
Effect of Electrodes Configurations on the Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz // WC2012 World Congress on Medical Physics and Biomedical Engineering Proceedings / Liu, Depei (ur.).
Peking, Kina, 2012. (poster, međunarodna recenzija, sažetak, znanstveni)


CROSBI ID: 582894 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Effect of Electrodes Configurations on the Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz

Autori
Lučev, Željka ; Krois, Igor ; Cifrek, Mario

Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni

Izvornik
WC2012 World Congress on Medical Physics and Biomedical Engineering Proceedings / Liu, Depei - , 2012

Skup
World Congress on Medical Physics and Biomedical Engineering

Mjesto i datum
Peking, Kina, 26.05.2012. - 31.05.2012

Vrsta sudjelovanja
Poster

Vrsta recenzije
Međunarodna recenzija

Ključne riječi
Electrodes Configurations; Capacitive Coupling; Intrabody Communication Channel

Sažetak
We investigate the effect of two electrode configurations on the capacitive IBC transmission characteristics in the frequency range 100 kHz–100 MHz on 11 test subjects at 5 transmitter-receiver distances. Higher transmission gain is achieved for the electrode configuration B, and shorter distances. The gain is distance-dependent in the whole frequency range for the configuration A, and above 2 MHz for the configuration B. Also, above approximately 10 MHz the length of the body signal path becomes a significant part of the wavelength, so the radiation and scattering effects cannot be neglected.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0362979-1554 - Neinvazivna mjerenja i postupci u biomedicini (Tonković, Stanko, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Željka Lučev Vasić (autor)

Avatar Url Mario Cifrek (autor)

Avatar Url Igor Krois (autor)


Citiraj ovu publikaciju:

Lučev, Željka; Krois, Igor; Cifrek, Mario
Effect of Electrodes Configurations on the Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz // WC2012 World Congress on Medical Physics and Biomedical Engineering Proceedings / Liu, Depei (ur.).
Peking, Kina, 2012. (poster, međunarodna recenzija, sažetak, znanstveni)
Lučev, Ž., Krois, I. & Cifrek, M. (2012) Effect of Electrodes Configurations on the Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz. U: Liu, D. (ur.)WC2012 World Congress on Medical Physics and Biomedical Engineering Proceedings.
@article{article, author = {Lu\v{c}ev, \v{Z}eljka and Krois, Igor and Cifrek, Mario}, editor = {Liu, D.}, year = {2012}, keywords = {Electrodes Configurations, Capacitive Coupling, Intrabody Communication Channel}, title = {Effect of Electrodes Configurations on the Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz}, keyword = {Electrodes Configurations, Capacitive Coupling, Intrabody Communication Channel}, publisherplace = {Peking, Kina} }
@article{article, author = {Lu\v{c}ev, \v{Z}eljka and Krois, Igor and Cifrek, Mario}, editor = {Liu, D.}, year = {2012}, keywords = {Electrodes Configurations, Capacitive Coupling, Intrabody Communication Channel}, title = {Effect of Electrodes Configurations on the Capacitive Intrabody Communication Channel from 100 kHz to 100 MHz}, keyword = {Electrodes Configurations, Capacitive Coupling, Intrabody Communication Channel}, publisherplace = {Peking, Kina} }