Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air


Arh, Gregor; Klasinc, Leo; Veber, Marjan; Pompe, Matevz
Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air // Journal of chromatography. A, 1218 (2011), 11; 1538-1543 doi:10.1016/j.chroma.2011.01.037 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 544504 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air

Autori
Arh, Gregor ; Klasinc, Leo ; Veber, Marjan ; Pompe, Matevz

Izvornik
Journal of chromatography. A (0021-9673) 1218 (2011), 11; 1538-1543

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
VOC ; Gas chromatography ; Mass spectrometry ; QSPR ; Response factor

Sažetak
Volatile organic compounds (VOCs) play an important role in the chemistry of the atmosphere and in biogeochemistry. They contribute to the oxidative capacity of the atmosphere, particle and air pollutants, as well as to the production of greenhouse gasses (for instance ozone). Among analytical techniques for their determination in the atmosphere gas chromatography coupled with mass spectrometry (GC-MS) offers several advantages. However, for an accurate quantification calibration with standard substances is necessary. A quantitative structure-property relationship (QSPR) model for the prediction of MS response factors was developed on basis of our experimental measurements for the quantification of ozone precursors present in the atmosphere. A linear correlation between chemical structures and response factors was established by using a 7-parameter MLR model. The average error in the prediction of response factors was calculated by cross-validation procedure and was below 20%, which is sufficient for the determination of VOCs in the air. The proposed procedure is time consuming so it is more suited for the quantification of tentatively identified organic compounds during the reprocessing of MS chromatograms in cases when the original sample is no longer available.

Izvorni jezik
Engleski

Znanstvena područja
Kemija



POVEZANOST RADA


Projekti:
098-0982915-2947 - Mjerenje i djelovanje atmosferskih oksidansa (Klasinc, Leo, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb

Profili:

Avatar Url Leo Klasinc (autor)

Poveznice na cjeloviti tekst rada:

doi dx.doi.org www.sciencedirect.com

Citiraj ovu publikaciju:

Arh, Gregor; Klasinc, Leo; Veber, Marjan; Pompe, Matevz
Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air // Journal of chromatography. A, 1218 (2011), 11; 1538-1543 doi:10.1016/j.chroma.2011.01.037 (međunarodna recenzija, članak, znanstveni)
Arh, G., Klasinc, L., Veber, M. & Pompe, M. (2011) Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air. Journal of chromatography. A, 1218 (11), 1538-1543 doi:10.1016/j.chroma.2011.01.037.
@article{article, author = {Arh, Gregor and Klasinc, Leo and Veber, Marjan and Pompe, Matevz}, year = {2011}, pages = {1538-1543}, DOI = {10.1016/j.chroma.2011.01.037}, keywords = {VOC, Gas chromatography, Mass spectrometry, QSPR, Response factor}, journal = {Journal of chromatography. A}, doi = {10.1016/j.chroma.2011.01.037}, volume = {1218}, number = {11}, issn = {0021-9673}, title = {Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air}, keyword = {VOC, Gas chromatography, Mass spectrometry, QSPR, Response factor} }
@article{article, author = {Arh, Gregor and Klasinc, Leo and Veber, Marjan and Pompe, Matevz}, year = {2011}, pages = {1538-1543}, DOI = {10.1016/j.chroma.2011.01.037}, keywords = {VOC, Gas chromatography, Mass spectrometry, QSPR, Response factor}, journal = {Journal of chromatography. A}, doi = {10.1016/j.chroma.2011.01.037}, volume = {1218}, number = {11}, issn = {0021-9673}, title = {Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air}, keyword = {VOC, Gas chromatography, Mass spectrometry, QSPR, Response factor} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati: