Influence of the Harmonics in the Load Current on Design of the Traction Transformers
Influence of the Harmonics in the Load Current on Design of the Traction Transformers // Proceedings of 31th Conference on transportation Systems with International Participations, Automation in Transportation 2011
Milano, Italija; Pula, Hrvatska, 2011. (predavanje, domaća recenzija, cjeloviti rad (in extenso), stručni)
CROSBI ID: 543054 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Influence of the Harmonics in the Load Current on Design of the Traction Transformers
Autori
Sitar, Ivan ; Meško, Nina
Vrsta, podvrsta i kategorija rada
Radovi u zbornicima skupova, cjeloviti rad (in extenso), stručni
Izvornik
Proceedings of 31th Conference on transportation Systems with International Participations, Automation in Transportation 2011
/ - , 2011
Skup
31th Conference on Transportation Systems with International Participation, Automation In Transportation 2011, Pula - Hrvatska / Croatia ; Milano - Italija / Italy ; 15–20.11.2011.
Mjesto i datum
Milano, Italija; Pula, Hrvatska, 15.11.2011. - 20.11.2011
Vrsta sudjelovanja
Predavanje
Vrsta recenzije
Domaća recenzija
Ključne riječi
EMU traction transformer; Impact of non sinusoidal load current. edy losses; temperature raise
Sažetak
The EMU transformer in operation is loaded with current which contains a considerable amount of harmonics. The harmonics in load current raise the eddy loss and stray flux loss and increases the total loss calculated or measured with purely sinusoidal current which is required to take in consideration when designing in order to correctly calculate the losses and conduct the thermal dimensioning of the transformer. In this paper the EMU transformer is analysed in order to obtain data about the influence of harmonic components in load current. Test results obtained in Končar D&ST test station under sinusoidal current loading conditions were compared to results of measurements performed during the loading conditions in service. The results of the analysis have shown the impact of higher load current harmonic components on the transformer's load losses and temperature rise.