Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods


Flegar-Meštrić, Zlata; Perkov, Sonja
Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods // Clinical chemistry and laboratory medicine, 44 (2006), 7; 898-903 doi:10.1515/CCLM.2006.148 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 542429 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods

Autori
Flegar-Meštrić, Zlata ; Perkov, Sonja

Izvornik
Clinical chemistry and laboratory medicine (1434-6621) 44 (2006), 7; 898-903

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
analytical quality specification; point-of -care testing; biosensor-based analysis; matrix effect.

Sažetak
The aim of the present study was the analytical evaluation of the biosensor-based methods for the measurement of electrolytes and substrates in the whole blood using Stat Profile Critical Care Xpress, (Nova Biomedical, Walthman, MA, USA) multiprofile analyzer and their comparison with routine laboratory methods. The imprecision and inaccuracy of the electrolytes and substrates measurement in the whole blood using STP CCX analyzer met the analytical quality specification required for near patient testing. The comparison results showed very close correlation between arterial whole-blood measurement on STP CCX analyzer and standard laboratory methods in arterial plasma or venous serum (r>0.9), althought slope and intercept values showed analytical differences in electrolytes measurement. The measurement of ionized cations (calcium, magnesium, sodium, potassium) in the different sample types (arterial whole blood, arterial plasma, venous serum samples) using STP CCX analyzer showed no significant mean differences (p>0.05). The STP CCX multiprofile point-of-care analyzer provides rapid and accurate simultaneous direct whole blood measurement of ionized electrolytes with activity-based ion-selective electrodes together with glucose, urea and creatinine measurement with biosensor-based substrate specific electrodes. The obtained whole blood results were comparable to the standard laboratory methods in arterial plasma or venous serum samples.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti



POVEZANOST RADA


Ustanove:
Klinička bolnica "Merkur"

Profili:

Avatar Url Zlata Flegar-Meštrić (autor)

Avatar Url Sonja Perkov (autor)

Poveznice na cjeloviti tekst rada:

doi www.degruyter.com

Citiraj ovu publikaciju:

Flegar-Meštrić, Zlata; Perkov, Sonja
Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods // Clinical chemistry and laboratory medicine, 44 (2006), 7; 898-903 doi:10.1515/CCLM.2006.148 (međunarodna recenzija, članak, znanstveni)
Flegar-Meštrić, Z. & Perkov, S. (2006) Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods. Clinical chemistry and laboratory medicine, 44 (7), 898-903 doi:10.1515/CCLM.2006.148.
@article{article, author = {Flegar-Me\v{s}tri\'{c}, Zlata and Perkov, Sonja}, year = {2006}, pages = {898-903}, DOI = {10.1515/CCLM.2006.148}, keywords = {analytical quality specification, point-of -care testing, biosensor-based analysis, matrix effect.}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/CCLM.2006.148}, volume = {44}, number = {7}, issn = {1434-6621}, title = {Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods}, keyword = {analytical quality specification, point-of -care testing, biosensor-based analysis, matrix effect.} }
@article{article, author = {Flegar-Me\v{s}tri\'{c}, Zlata and Perkov, Sonja}, year = {2006}, pages = {898-903}, DOI = {10.1515/CCLM.2006.148}, keywords = {analytical quality specification, point-of -care testing, biosensor-based analysis, matrix effect.}, journal = {Clinical chemistry and laboratory medicine}, doi = {10.1515/CCLM.2006.148}, volume = {44}, number = {7}, issn = {1434-6621}, title = {Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods}, keyword = {analytical quality specification, point-of -care testing, biosensor-based analysis, matrix effect.} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font