Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 524364

Acute Animal and Human Study of a Tensiometric Pacing Lead Sensor Based on Triboelectricity


Tomašić, Danko; Ferek-Petrić, Božidar; Brusich, Sandro; Accardo, Agostino P.
Acute Animal and Human Study of a Tensiometric Pacing Lead Sensor Based on Triboelectricity // IEEE transactions on biomedical engineering, 58 (2011), 8; 2290-2296 doi:10.1109/TBME.2011.2148198 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 524364 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Acute Animal and Human Study of a Tensiometric Pacing Lead Sensor Based on Triboelectricity

Autori
Tomašić, Danko ; Ferek-Petrić, Božidar ; Brusich, Sandro ; Accardo, Agostino P.

Izvornik
IEEE transactions on biomedical engineering (0018-9294) 58 (2011), 8; 2290-2296

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
cardiac leads; hemodynamic sensor; triboelectricity

Sažetak
Cardiac contractions bend the implanted cardiac lead body, and extend and compress the lead conductors, their insulation, and the inserted stylet. Magnitude of lead deflection depends on cardiac muscle contraction forces. The purpose of this study was to measure the charge generated due to triboelectric effect between one of the lead conductors and the inserted stylet. The charge wasmeasured by a differential charge amplifier being connected to an isolation amplifier and power supply. Sensor signal, ECG, and intracardiac electrograms were acquired. Threemodels of customdesigned leads were implanted in eight sheep. Measurements were done in 18 patients undergoing pacemaker implantation and replacement procedures. Atrial and ventricular tensiometric signals were recorded in dual chamber and in single-lead ventricular diastolic dysfunction patients. Recordings in sinus rhythm at various atrioventricular intervals and in supraventricular tachycardia were done. On average, charge variation between 1 and 600 pC was measured. Tensiometric stylet could be feasible hemodynamic sensor for myocardial contraction detection. Its main advantage is that it is easily exchangeable and universal for all leads.

Izvorni jezik
Engleski

Znanstvena područja
Elektrotehnika



POVEZANOST RADA


Projekti:
036-0362979-1554 - Neinvazivna mjerenja i postupci u biomedicini (Tonković, Stanko, MZO ) ( CroRIS)

Ustanove:
Fakultet elektrotehnike i računarstva, Zagreb

Profili:

Avatar Url Božidar Ferek-Petrić (autor)

Avatar Url Sandro Brusich (autor)

Poveznice na cjeloviti tekst rada:

doi ieeexplore.ieee.org

Citiraj ovu publikaciju:

Tomašić, Danko; Ferek-Petrić, Božidar; Brusich, Sandro; Accardo, Agostino P.
Acute Animal and Human Study of a Tensiometric Pacing Lead Sensor Based on Triboelectricity // IEEE transactions on biomedical engineering, 58 (2011), 8; 2290-2296 doi:10.1109/TBME.2011.2148198 (međunarodna recenzija, članak, znanstveni)
Tomašić, D., Ferek-Petrić, B., Brusich, S. & Accardo, A. (2011) Acute Animal and Human Study of a Tensiometric Pacing Lead Sensor Based on Triboelectricity. IEEE transactions on biomedical engineering, 58 (8), 2290-2296 doi:10.1109/TBME.2011.2148198.
@article{article, author = {Toma\v{s}i\'{c}, Danko and Ferek-Petri\'{c}, Bo\v{z}idar and Brusich, Sandro and Accardo, Agostino P.}, year = {2011}, pages = {2290-2296}, DOI = {10.1109/TBME.2011.2148198}, keywords = {cardiac leads, hemodynamic sensor, triboelectricity}, journal = {IEEE transactions on biomedical engineering}, doi = {10.1109/TBME.2011.2148198}, volume = {58}, number = {8}, issn = {0018-9294}, title = {Acute Animal and Human Study of a Tensiometric Pacing Lead Sensor Based on Triboelectricity}, keyword = {cardiac leads, hemodynamic sensor, triboelectricity} }
@article{article, author = {Toma\v{s}i\'{c}, Danko and Ferek-Petri\'{c}, Bo\v{z}idar and Brusich, Sandro and Accardo, Agostino P.}, year = {2011}, pages = {2290-2296}, DOI = {10.1109/TBME.2011.2148198}, keywords = {cardiac leads, hemodynamic sensor, triboelectricity}, journal = {IEEE transactions on biomedical engineering}, doi = {10.1109/TBME.2011.2148198}, volume = {58}, number = {8}, issn = {0018-9294}, title = {Acute Animal and Human Study of a Tensiometric Pacing Lead Sensor Based on Triboelectricity}, keyword = {cardiac leads, hemodynamic sensor, triboelectricity} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font