Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications
Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications // Radiation measurements, 46 (2011), 12; 1582-1585 doi:10.1016/j.radmeas.2011.05.042 (međunarodna recenzija, članak, znanstveni)
CROSBI ID: 514084 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications
Autori
Knežević, Željka ; Beck, Natko ; Milković, Đurđica ; Miljanić, Saveta ; Ranogajec-Komor, Maria
Izvornik
Radiation measurements (1350-4487) 46
(2011), 12;
1582-1585
Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni
Ključne riječi
RPL ; glass dosimeters ; LiF:Mg ; Cu ; P ; energy dependence ; IEC standards ; medical dosimetry ; paediatric chest X-ray diagnostics
Sažetak
Radiophotoluminescence (RPL) dosimetry systems are under permanent development. The following dosimetric characteristics of the GD-352M RPL glass dosimeter with FGD-1000 reader (Dose Ace system) developed for medical applications were investigated: uniformity/batch homogeneity, reproducibility, linearity, detection threshold, energy dependence in air and on phantom. Some characteristics were compared to two kinds of LiF ; Cu, Mg, P TLDs: GR-200A (China) and TLD-100H (Harshaw). The characteristics investigated fulfill the requirements of the IEC 62387-1:2007 Standard for personal and environmental dosimetry (IEC, 2007). These dosimetry systems were applied in paediatric chest X-ray diagnostics on 60 patients. The dosimetry results with both dosimetry systems showed a good correlation of dose measured on the back of the patient with the body mass index (BMI) on examination by two technicians (average dose 0.12-0.19 mSv). Higher doses (0.33-0.39 mSv) were found on the patients examined by the third technician. Measurements on further 40 patients following additional consulting and education of the technicians showed dose reduction (0.13-0.18 mSv for all 3 technicians).
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kemija, Kliničke medicinske znanosti
Napomena
Rad je prezentiran na skupu 16th Solid State Dosimetry Conference, održanom od 19.-24.09.2011., Sydney, Australija.
POVEZANOST RADA
Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)
Ustanove:
Institut "Ruđer Bošković", Zagreb,
Klinička bolnica "Sveti Duh",
Dječja bolnica Srebrnjak
Profili:
Željka Knežević Medija
(autor)
Saveta Miljanić
(autor)
Ferencne Ranogajec
(autor)
Natko Beck
(autor)
Đurđica Milković
(autor)
Citiraj ovu publikaciju:
Časopis indeksira:
- Current Contents Connect (CCC)
- Web of Science Core Collection (WoSCC)
- Science Citation Index Expanded (SCI-EXP)
- SCI-EXP, SSCI i/ili A&HCI
- Scopus