Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications


Knežević, Željka; Beck, Natko; Milković, Đurđica; Miljanić, Saveta; Ranogajec-Komor, Maria
Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications // Radiation measurements, 46 (2011), 12; 1582-1585 doi:10.1016/j.radmeas.2011.05.042 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 514084 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications

Autori
Knežević, Željka ; Beck, Natko ; Milković, Đurđica ; Miljanić, Saveta ; Ranogajec-Komor, Maria

Izvornik
Radiation measurements (1350-4487) 46 (2011), 12; 1582-1585

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
RPL ; glass dosimeters ; LiF:Mg ; Cu ; P ; energy dependence ; IEC standards ; medical dosimetry ; paediatric chest X-ray diagnostics

Sažetak
Radiophotoluminescence (RPL) dosimetry systems are under permanent development. The following dosimetric characteristics of the GD-352M RPL glass dosimeter with FGD-1000 reader (Dose Ace system) developed for medical applications were investigated: uniformity/batch homogeneity, reproducibility, linearity, detection threshold, energy dependence in air and on phantom. Some characteristics were compared to two kinds of LiF ; Cu, Mg, P TLDs: GR-200A (China) and TLD-100H (Harshaw). The characteristics investigated fulfill the requirements of the IEC 62387-1:2007 Standard for personal and environmental dosimetry (IEC, 2007). These dosimetry systems were applied in paediatric chest X-ray diagnostics on 60 patients. The dosimetry results with both dosimetry systems showed a good correlation of dose measured on the back of the patient with the body mass index (BMI) on examination by two technicians (average dose 0.12-0.19 mSv). Higher doses (0.33-0.39 mSv) were found on the patients examined by the third technician. Measurements on further 40 patients following additional consulting and education of the technicians showed dose reduction (0.13-0.18 mSv for all 3 technicians).

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Kemija, Kliničke medicinske znanosti

Napomena
Rad je prezentiran na skupu 16th Solid State Dosimetry Conference, održanom od 19.-24.09.2011., Sydney, Australija.



POVEZANOST RADA


Projekti:
098-0982904-2954 - Fizičko-kemijski učinci ionizirajućih zračenja u materijalima (Mihaljević, Branka, MZOS ) ( CroRIS)

Ustanove:
Institut "Ruđer Bošković", Zagreb,
Klinička bolnica "Sveti Duh",
Dječja bolnica Srebrnjak

Poveznice na cjeloviti tekst rada:

doi www.sciencedirect.com dx.doi.org

Citiraj ovu publikaciju:

Knežević, Željka; Beck, Natko; Milković, Đurđica; Miljanić, Saveta; Ranogajec-Komor, Maria
Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications // Radiation measurements, 46 (2011), 12; 1582-1585 doi:10.1016/j.radmeas.2011.05.042 (međunarodna recenzija, članak, znanstveni)
Knežević, Ž., Beck, N., Milković, Đ., Miljanić, S. & Ranogajec-Komor, M. (2011) Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications. Radiation measurements, 46 (12), 1582-1585 doi:10.1016/j.radmeas.2011.05.042.
@article{article, author = {Kne\v{z}evi\'{c}, \v{Z}eljka and Beck, Natko and Milkovi\'{c}, \DJur\djica and Miljani\'{c}, Saveta and Ranogajec-Komor, Maria}, year = {2011}, pages = {1582-1585}, DOI = {10.1016/j.radmeas.2011.05.042}, keywords = {RPL, glass dosimeters, LiF:Mg, Cu, P, energy dependence, IEC standards, medical dosimetry, paediatric chest X-ray diagnostics}, journal = {Radiation measurements}, doi = {10.1016/j.radmeas.2011.05.042}, volume = {46}, number = {12}, issn = {1350-4487}, title = {Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications}, keyword = {RPL, glass dosimeters, LiF:Mg, Cu, P, energy dependence, IEC standards, medical dosimetry, paediatric chest X-ray diagnostics} }
@article{article, author = {Kne\v{z}evi\'{c}, \v{Z}eljka and Beck, Natko and Milkovi\'{c}, \DJur\djica and Miljani\'{c}, Saveta and Ranogajec-Komor, Maria}, year = {2011}, pages = {1582-1585}, DOI = {10.1016/j.radmeas.2011.05.042}, keywords = {RPL, glass dosimeters, LiF:Mg, Cu, P, energy dependence, IEC standards, medical dosimetry, paediatric chest X-ray diagnostics}, journal = {Radiation measurements}, doi = {10.1016/j.radmeas.2011.05.042}, volume = {46}, number = {12}, issn = {1350-4487}, title = {Characterization of RPL and TL dosimetry systems and comparison in medical dosimetry applications}, keyword = {RPL, glass dosimeters, LiF:Mg, Cu, P, energy dependence, IEC standards, medical dosimetry, paediatric chest X-ray diagnostics} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font