Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 510975

Radiation protection of patients in diagnostic radiology : Status of practice in five Eastern-European countries, based on IAEA project


Ciraj Bjelac, Olivera; Beganović, Adnan; Faj, Dario; Gershan, Vesna; Ivanović, Sonja; Videnović, Ivan R.; Rehani, Madan M.
Radiation protection of patients in diagnostic radiology : Status of practice in five Eastern-European countries, based on IAEA project // European journal of radiology, 79 (2011), 2; e70-e73 doi:10.1016/j.ejrad.2011.03.075 (međunarodna recenzija, članak, znanstveni)


CROSBI ID: 510975 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Radiation protection of patients in diagnostic radiology : Status of practice in five Eastern-European countries, based on IAEA project

Autori
Ciraj Bjelac, Olivera ; Beganović, Adnan ; Faj, Dario ; Gershan, Vesna ; Ivanović, Sonja ; Videnović, Ivan R. ; Rehani, Madan M.

Izvornik
European journal of radiology (0720-048X) 79 (2011), 2; E70-e73

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
radiation safety in interventional procedure; radiation safety radiography; radiation safety mammography; radiation safety computed tomography; radiation protection; radiation dose management

Sažetak
The purpose of this work was to investigate status of imaging technology and practice in five countries in Eastern-European region and evaluate the impact of IAEA projects on radiation protection of patients. Information collected using standardized IAEA protocol included status of technology, practices and patient dose levels in interventional procedure, radiography, mammography and computed tomography (CT). In spite of increased number of digital units, single phase generators or units older than 30 year are still in use. Examples of obsolete practice such as using fluoroscopy for positioning, photofluorography, chest fluoroscopy and soft-beam technique for chest radiography are also in use. Modern multi-slice CT or digital mammography units are available ; however, there is lack of adequate radiation protection and medical physics support in hospitals. Information on patient doses in interventional procedures, conventional radiography, mammography and CT was collected to have baseline data and corrective measures were proposed with appropriate follow up actions taken.

Izvorni jezik
Engleski

Znanstvena područja
Fizika, Temeljne medicinske znanosti



POVEZANOST RADA


Projekti:
219-2192382-2386 - Razvoj modela funkcije cirkulacijskog sustava ovisnog o arterijskoj elastičnosti (Marić, Svjetlana, MZOS ) ( CroRIS)
286-0000000-3212 - Radioaktivnost u okolišu, detekcija i primjena (Planinić, Josip, MZOS ) ( CroRIS)

Ustanove:
Klinički bolnički centar Osijek,
Medicinski fakultet, Osijek,
Sveučilište u Osijeku - Odjel za fiziku

Profili:

Avatar Url Dario Faj (autor)

Citiraj ovu publikaciju:

Ciraj Bjelac, Olivera; Beganović, Adnan; Faj, Dario; Gershan, Vesna; Ivanović, Sonja; Videnović, Ivan R.; Rehani, Madan M.
Radiation protection of patients in diagnostic radiology : Status of practice in five Eastern-European countries, based on IAEA project // European journal of radiology, 79 (2011), 2; e70-e73 doi:10.1016/j.ejrad.2011.03.075 (međunarodna recenzija, članak, znanstveni)
Ciraj Bjelac, O., Beganović, A., Faj, D., Gershan, V., Ivanović, S., Videnović, I. & Rehani, M. (2011) Radiation protection of patients in diagnostic radiology : Status of practice in five Eastern-European countries, based on IAEA project. European journal of radiology, 79 (2), e70-e73 doi:10.1016/j.ejrad.2011.03.075.
@article{article, author = {Ciraj Bjelac, Olivera and Beganovi\'{c}, Adnan and Faj, Dario and Gershan, Vesna and Ivanovi\'{c}, Sonja and Videnovi\'{c}, Ivan R. and Rehani, Madan M.}, year = {2011}, pages = {e70-e73}, DOI = {10.1016/j.ejrad.2011.03.075}, keywords = {radiation safety in interventional procedure, radiation safety radiography, radiation safety mammography, radiation safety computed tomography, radiation protection, radiation dose management}, journal = {European journal of radiology}, doi = {10.1016/j.ejrad.2011.03.075}, volume = {79}, number = {2}, issn = {0720-048X}, title = {Radiation protection of patients in diagnostic radiology : Status of practice in five Eastern-European countries, based on IAEA project}, keyword = {radiation safety in interventional procedure, radiation safety radiography, radiation safety mammography, radiation safety computed tomography, radiation protection, radiation dose management} }
@article{article, author = {Ciraj Bjelac, Olivera and Beganovi\'{c}, Adnan and Faj, Dario and Gershan, Vesna and Ivanovi\'{c}, Sonja and Videnovi\'{c}, Ivan R. and Rehani, Madan M.}, year = {2011}, pages = {e70-e73}, DOI = {10.1016/j.ejrad.2011.03.075}, keywords = {radiation safety in interventional procedure, radiation safety radiography, radiation safety mammography, radiation safety computed tomography, radiation protection, radiation dose management}, journal = {European journal of radiology}, doi = {10.1016/j.ejrad.2011.03.075}, volume = {79}, number = {2}, issn = {0720-048X}, title = {Radiation protection of patients in diagnostic radiology : Status of practice in five Eastern-European countries, based on IAEA project}, keyword = {radiation safety in interventional procedure, radiation safety radiography, radiation safety mammography, radiation safety computed tomography, radiation protection, radiation dose management} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati:





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font