Pregled bibliografske jedinice broj: 48784
Comparison of high resolution transmission electron microscopy and low frequency Raman scattering in determination of particles size distribution of nanosized TiO2
Comparison of high resolution transmission electron microscopy and low frequency Raman scattering in determination of particles size distribution of nanosized TiO2 // Abstracts Book of the 1st International workshop on nanoscale spectroscopy and its applications to semiconductor research / Heun, Stefano (ur.).
Trst: Elettra Sincrotrone Trieste, 2000. str. 48-48 (pozvano predavanje, međunarodna recenzija, sažetak, znanstveni)
CROSBI ID: 48784 Za ispravke kontaktirajte CROSBI podršku putem web obrasca
Naslov
Comparison of high resolution transmission electron microscopy and low frequency Raman scattering in determination of particles size distribution of nanosized TiO2
Autori
Ivanda, Mile (predavač) ; Tonejc, Anđelka M. ; Djerdj, Igor ; Gotić, Marijan ; Musić, Svetozar ; Mariotto, Gino
Vrsta, podvrsta i kategorija rada
Sažeci sa skupova, sažetak, znanstveni
Izvornik
Abstracts Book of the 1st International workshop on nanoscale spectroscopy and its applications to semiconductor research
/ Heun, Stefano - Trst : Elettra Sincrotrone Trieste, 2000, 48-48
Skup
1st International workshop on nanoscale spectroscopy and its applications to semiconductor research
Mjesto i datum
Trst, Italija, 11.12.2000. - 15.12.2000
Vrsta sudjelovanja
Pozvano predavanje
Vrsta recenzije
Međunarodna recenzija
Ključne riječi
TiO2 nanoparticles; size distribution; Raman scattering
Sažetak
Size distribution of TiO2 nanoparticles synthesized by sol-gel method are determined by high resolution transmission electron microscopy (HRTEM) and compared with those determined by low frequency Raman scattering (LFRS). The methodology for the determination of nanosized particle distribution by LFRS is described. It is based on n-1 dependence of the Raman light to vibration coupling coefficient and on the fact that each nanocrystallite of diameter D vibrates with its own eigen frequency n~1/D. The effect of the particle vibrational lifetime on the shape of distribution is analyzed and found to be negligible for the weakly connected TiO2 particles. Fig. 1 shows comparison of the HRTEM and LFRS TiO2 size distributions. On the basis of comparison of particle size distributions deduced by HRTEM and LFRS on 15 different samples, the Raman spectroscopy shows to be simple, fast method that has favorable statistic over the macroscopic probe volume and that enables ''in situ'' measurements.
Izvorni jezik
Engleski
Znanstvena područja
Fizika, Kemija
POVEZANOST RADA
Ustanove:
Institut "Ruđer Bošković", Zagreb,
Prirodoslovno-matematički fakultet, Zagreb
Profili:
Svetozar Musić
(autor)
Anđelka Tonejc
(autor)
Igor Đerđ
(autor)
Marijan Gotić
(autor)
Mile Ivanda
(autor)